| 2017-05-17 10:40:14 | FAILED |
| | |
| | PLEASE PROVIDE WRITTEN RESPONSES. |
| | |
| | 1) THE SITE DATE TABLE ON SHEET SP-3 SHOWS AN INCREASE |
| | IN THE SQUARE FOOTAGE OF THE ACADEMIC BUILDING TO |
| | 16,030 SF, YET THIS IS NOT REFLECTED ON THE BUILDING |
| | SHOWN ON THE PLAN - STILL SHOWS THE BUILDING AS HAVING |
| | 15,996 SF. THE BUILDING ON SHEET C.1 ALSO SHOWS AS |
| | 15,966. PLANS MUST BE INTERNALLY CONSISTENT. |
| | |
| | 2) THE SETBACKS LISTED ON THE SITE DATA TABLE FOR THE |
| | EXISTING PBDA CONTINUE TO SHOW THE INCORRECT FRONT |
| | (SOUTH) AND REAR (NORTH) SETBACK. NOTE: THIS WAS |
| | CORRECTED ON THE PLANS APPROVED AS PART OF THE MINOR |
| | PLANNED DEVELOPMENT AMENDMENT DATED APRIL 21, 2017. |
| | |
| | 3) THE NEW RAMP BETWEEN THE EXISTING AND THE PROPOSED |
| | BUILDING IS NOT SHOWN ON SP-3. ALL PLANS SHALL SHOW THE |
| | SAME CONDITIONS. |
| | |
| | 4) THE LOCATION OF THE NEW RAMP COMBINED WITH THE FENCE |
| | TO THE WEST OF THE BICYCLE RACKS, RESULT IN THE RACKS |
| | BEING BLOCKED AND NON-FUNCTIONAL. RELOCATE THE FENCE, |
| | THE BICYCLE RACKS OR THE RAMP SO THAT STUDENTS OR |
| | FACULTY WHO RIDE THEIR BICYCLES TO THE CAMPUS CAN |
| | ACCESS THE BICYCLE RACKS TO SECURE THEIR BICYCLES. |
| | |
| | 5) SHEET AS3.2 SHOWS A NEW CANOPY PLAN DETAIL WHICH |
| | INCLUDES THE PROPOSED RAMP. THIS FAILS TO SHOW THE |
| | BICYCLE RACK AND FENCE MENTIONED IN COMMENT NO. 4. IT |
| | NEEDS TO SHOW ALL FEATURES IN THE AREA. |
| | |
| | 6) SHEETS A1.01 AND A1.1 NEED TO SHOW THE BICYCLE RACK |
| | IF IT WILL REMAIN IN PLACE (THIS REQUIRES THE |
| | RELOCATION OF THE FENCE). |
| | |
| | 7) THE OIL AND GAS INTERCEPTOR SHOWN ON SHEET C.1 MUST |
| | BE RELOCATED SO THAT IT DOES NOT INTERFERE WITH THE |
| | TREES APPROVED ON THE LANDSCAPE PLAN IN THE SAME |
| | LOCATION. PLEASE NOTE THAT THE CURRENTLY SHOWN |
| | IMPERVIOUS AREAS INCLUDE THE REQUIRED LANDSCAPE, SO |
| | STAFF RECOMMENDS THAT THE OGI BE LOCATED UNDERNEATH A |
| | SIDEWALK OR OTHER PAVED AREA. |
| | |
| | 8) THE ROOF PLAN AND ELEVATIONS DO NOT SHOW ANY |
| | MECHANICAL EQUIPMENT FOR THE ELEVATOR EXTENDING ABOVE |
| | THE ROOF. PLEASE VERIFY THIS IS CORRECT. STAFF IS USED |
| | TO SEEING ELEVATORS HAVE EQUIPMENT EXTEND ABOVE THE |
| | ROOFLINE. |
| | |
| | 9) A NEW MINOR AMENDMENT IS REQUIRED TO REFLECT THE |
| | CHANGES BASED ON THE NEW BUILDING SQUARE FOOTAGE AND |
| | THE RAMP. |
| | |