| 2015-04-20 18:49:25 | PLAN REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE GARAGE STRUCTURE WILL REQUIRE A STRUCTURAL |
| | ANALYSIS (907.2). SUBMIT TWO SETS OF A SIGNED AND |
| | SEALED STRUCTURAL ANALYSIS ON THE EXISTING GARAGE FROM |
| | A FLORIDA LICENSED ENGINEER. |
| | GENERAL AFTER THE FACT PERMITS |
| | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY |
| | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR |
| | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL |
| | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 |
| | & FBC 117. |
| | |
| | |
| | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF |
| | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, |
| | STRUCTURAL MULLIONS, EXTERIOR DOOR TYPES AND SIMPSON |
| | CONNECTORS. (SINGLE HUNG WINDOW AND MULLION PRODUCT |
| | APPROVALS WERE SUBMITTED WITH ORIGINAL APPLICATION.) |
| | NOTE: IF THE PRODUCT APPROVAL NUMBERS FOR THE SIMPSON |
| | CONNECTORS ARE LISTED ON THE PLANS THEIR PRODUCT |
| | APPROVALS DO NOT HAVE TO BE SUBMITTED. NOTE: THE |
| | PRODUCT APPROVALS SUBMITTED FOR THE DOORS IS FOR A |
| | SINGLE OUTSWING DOOR. SUBMIT THE ONES FOR DOUBLE |
| | OUTSWING DOORS. SPECIFY THE WINDOWS THAT WILL BE |
| | INSTALLED BY MARKING THE APPROPRIATE ONES ARE THEIR |
| | DESIGN PRESSURES ON THE TABLES IN THE PRODUCT |
| | APPROVALS. |
| | |
| | 3)SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION |
| | SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER |
| | CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS |
| | 402 OR 405. |
| | FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE |
| | COMPLIANCE CERTIFICATION. |
| | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER |
| | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL |
| | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE |
| | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR |
| | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR |
| | RENOVATION. |
| | |
| | 4) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE |
| | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER |
| | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN |
| | ADDRESSED. |
| | |
| | |
| | |