| Plan Review Notes For Permit 15020685 |
| Permit Number |
15020685 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-03-07 04:52:46 | 1) SUBMIT A SITE PLAN SHOWING THE CONNECTION AND | | | LOCATION OF THE WATER & SEWER SYSTEM TO THE MODULAR | | | BUILDING. THE MINIMUM SIZE WATER SERVICE TO THE | | | STRUCTURE SHALL BE 3/4" PER 2010 FPC SEC.603.1. | | | 2) AN APPROVED BACKFLOW PREVENTER SHALL BE INSTALLED ON | | | THE WATER SERVICE AT THE METER PER WPB CITY ORDINANCE | | | SEC.90-33. A MINIMUM OF A REDUCED PRESSURE ZONE | | | BACKFLOW PREVENTION ASSEMBLY PER THE CITY OF WPB CROSS | | | CONNECTION MANUAL & 2010 FPC SEC.608.1.SUBMIT 2 COPIES | | | OF THE MANUF. SPECIFICATIONS FOR THE BFP DEVICE. | | | 3) INDICATE ON THE PLAN IF THE BUILDING WILL BE | | | CONNECTED TO A SANITARY SEWER OR A HOLDING TANK. IF TO | | | A HOLDING TANK, SHOW THE SIZE AND LOCATION OF THE TANK. | | | A PERMIT MAY BE REQUIRED FROM THE PALM BEACH COUNTY | | | HEALTH DEPT.ALSO, IF TO A HOLDING TANK, SUBMIT A COPY | | | OF THE PUMP OUT CONTRACT TO CONFIRM THE TSNK WILL BE | | | MAINTAINED IN A SANITARY CONDITION. 2010 FPC SEC.311.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|