| Plan Review Notes For Permit 15020671 |
| Permit Number |
15020671 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-02-24 12:17:39 | FEB.23, 2015 | | | REVISION # 15020671 GAS REVISION | | | MASTER PERMIT # 14070406 | | | 1)SUBMIT MANUFACTURER?S SPECIFICATIONS /INSTALLATION | | | MANUAL FOR ALL NEW AND/OR ADDITIONAL GAS EQUIPMENT | | | BEING INSTALLED. WPB AMEND. TO 2010 FBC | | | SEC.107.2.1.EQUIPMENT SHALL BE LISTED AND LABELED PER | | | THE 2010 FBC FUEL GAS CODE SEC.301.3. | | | 2) INDICATE ON THE PLAN THE TYPE OF PIPE BEING | | | INSTALLED. WPB AMEND. TO 2010 FBC SEC.107.2.1. | | | 3 ) INDICATE THE BTU LOAD OF EACH PIECE OF GAS | | | EQUIPMENT AND THE TOTAL BTU LOAD ON THE SYSTEM. | | | 4) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2010 | | | FBC FUEL GAS CODE SEC.304. | | | 5) INDICATE THE DELIVERY PRESSURE OF THE GAS PER THE | | | 2010 FUEL GAS CODE SEC.402.2. | | | 6) SUBMIT A DETAIL SHOWING THE TYPE, SIZE AND | | | TERMINATION LOCATIONS OF ALL GAS VENTS PER THE 2010 FBC | | | FUEL GAS CODE SECS.502 THROUGH 505. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|