Plan Review Notes
Plan Review Notes For Permit 15020591
Permit Number 15020591
Review Stop B
Sequence Number 1
Notes
Date Text
2015-02-26 08:22:28BUILDING PLAN REVIEW
 PERMIT: 15020591
 ADD: 777 S FLAGLER #3RD FLOOR
 CONT: CITY CONSTRUCTION GROUP
 TEL: (305)448-1118
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MAY 11, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
  
 1ST REVIEW
 DATE: THURS. FEB. 26/ 2015
 ACTION: DENIED
  
 1) SHEET LS 1.03 PLEASE SHOW COMPLIANCE WITH 2010
 FBC-ACCESSIBILITY SECTION 404.2.4 MANEUVERING
 CLEARANCES AT DOORS FOR DOOR , 3019, 3020,3032, 3033,
 3042, 3043, 3087 & 3095. SEE FL ACCESS. CODE TABLE
 404.2.4.1 & FIGURE 404.2.1(A), NOTE THE
 DISPROPROTIONATE COST OF UP TO $174,000 IS TO BE SPENT
 IN ACCESSIBLE UPGRADES. FL ACCESS CODE 202.4.1.
  
 2) SHEET LS 1.03 SHOWS A TOTAL SQ. FOOTAGE OF 19,774
 SQ. FT. TEN % OF THE FLOOR AREA WOULD BE 1,977 SQ. FT.
 THE ASSEMBLY OCCUPANCY SHOWS 2001 SQ. FEET WITHOUT THE
 BREAK ROOM BEING INCLUDED UPDATE BREAK ROOM TO A
 ASSEMBLY USAGE. THIS PUTS THE ASSEMBLY PORTION OF
 OCCUPANCY FROM BEING AN ACCESSORY OCCUPANCY TO A MIXED
 OCCUPANCY. 2010 FBC-B 508.2.1 THE ASSEMBLY USE AREAS
 MAY BE UNDER 750 SQ FT IN VARIOUS AERAS BUT WHEN
 TOTALED TOGETHER THEY EXCEED THE 10 % OF THE FLOOR
 PLATE CREATING A MIXED OCCUPANCY. FBC-B TABLE 508.4
 WILL REQUIRE A 1 HR. OCCUPANCY SEPARATION WAL AND TABLE
 7L5.4 OPENING PROTECTIVES WILL ALSO REQUIRE RATED
 DOORS.
  
 3) SHEET A6.01 SHOWS VARIOUS GLAS WALL DETAILS 7, 8 & 9
 THEY REFERANCE DETAILS ON SHEET A7.01 DETAIL# 3 AND
 A7.02 DETAIL # 8 ALL REFERANCE SEE THE GLASS SCHEDULE
 BUT NO SCHEDULE COULD BE FOUND. PLEASE PROVIDE
 COMPLIANCE WITH 2010 FBC-B 2406.4 HAZARDOUS LOCATIONS.
  
 JAMES A. WITMER CBO