2015-02-18 15:26:09PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE STRUCTURE IS LOCATED WITHIN 600 FEET OF THE
 INTERCOASTAL WATERWAY AND IS THEREFORE CONSIDERED
 EXPOSURE CATEGORY "D". THE MAXIMUM DESIGN PRESSURE FOR
 THE ROOFING SYSTEM THAT YOU SUBMITTED IS -45 PSF, WHICH
 IS NOT ENOUGH TO RESIST THE REQUIRED WIND LOADS. SUBMIT
 TWO SETS OF SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 ENHANCED FASTENING AS REQUIRED BY LIMITATION NUMBER 7
 ON PAGE 16 OF NOA NO. 13-1022.15
  