| 2015-02-19 14:39:35 | BUILDING PLAN REVIEW |
| | PERMIT: 15020445 |
| | ADD: 1501 NORTHPOINT PKWY # 103 |
| | CONT: PHILIP E. JOHNSON |
| | TEL: (561)262-1795 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: THURS.FEB. 19/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 1.1 INDICATES A EXISITNG 2 STORY ATRIUM A |
| | BUSINESS OCCUPANCY. SHEET 2.1 NOW SHOWS A PROPOSED |
| | ASSEMBLY OCCUPANCY WITH A CASED OPENING BETWEEN THE 2 |
| | OCCUPANCIES (STORAGE AS WELL AS BUSINESS OCCUPANCIES). |
| | PLEASE SHOW COMPLIANCE WITH 2010 FBC-B TABLE 508.4 1 |
| | HOUR SEPARATION FOR SPRINKLERS, 2 HOURS FOR |
| | NON-SPRINKLERED BUILDING. |
| | |
| | 2) PLEASE ALSO SEE ON SHEET A2.1 (2) ACCESSIBILITY |
| | ISSUES THAT ARE FOUND ON THE 2ND LEVEL AND NO VERTICAL |
| | ACCESSIBILITY, A BREAK ROOM AND A CONFERANCE ROOM, BOTH |
| | NOT SHOWN ON THE 1ST FLOOR. |
| | |
| | 2A) 2010 FL ACC. CODE 206.2.3 MULTI-STORY BUILDINGS AND |
| | FACILITIES. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT |
| | EACH STORY AND MEZZANINE IN MULTI-STORY BUILDINGS AND |
| | FACILITIES. NOTWITHSTANDING THE REQUIREMENTS AND |
| | EXCEPTIONS OF THIS SECTION, SECTION 201.1.1 SHALL |
| | APPLY. |
| | |
| | 2010 FL ACC. CODE 201.1.1 VERTICAL ACCESSIBILITY. |
| | SECTIONS 553.501-553.513, F.S., AND THE ADA STANDARDS |
| | FOR ACCESSIBLE DESIGN DO NOT RELIEVE THE OWNER OF ANY |
| | BUILDING, STRUCTURE OR FACILITY GOVERNED BY THOSE |
| | SECTIONS FROM THE DUTY TO PROVIDE VERTICAL |
| | ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE |
| | OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER THE |
| | STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN SUCH |
| | BUILDING, STRUCTURE OR FACILITY. |
| | |
| | 2010 FL ACC. CODE 202.4.2 ACCESSIBLE FEATURES IN THE |
| | EVENT OF DISPROPORTIONALITY.WHEN THE COST OF |
| | ALTERATIONS NECESSARY TO MAKE THE PATH OF TRAVEL TO THE |
| | ALTERED AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO |
| | THE COST OF THE OVERALL ALTERATION, THE PATH OF TRAVEL |
| | SHALL BE MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE |
| | MADE ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE |
| | COSTS. IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO |
| | PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS |
| | THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING |
| | ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE |
| | ROUTE TO THE ALTERED AREA; (III) AT LEAST ONE |
| | ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| | ALARMS. |
| | |
| | 2B) SHEET A2.1 INDICATES IN THE BREAK ROOM A NEW 2 BOWL |
| | SINK W/ GARBAGE DISPOSAL, PLANS FAIL TO PROVIDE |
| | COMPLIANCE WITH; |
| | 2010 FL ACC. CODE 606.1-5. |
| | |
| | 3) PLANS INDICATE IN THE WAREHOUSE AREA NEW DOCK |
| | LEVELERS BY OTHERS, IS THIS TO BE UNDER THIS PERMIT? OR |
| | IS THIS DELEGATED ENGINEERING UNDER THIS PERMIT? |
| | 107.2.1.3 ADDITIONAL INFORMATION IS EQUIRED. |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |