| Notes |
| Date |
Text |
| 2015-03-03 15:50:42 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. | | | | | | 2. FOR BEDROOM WINDOWS WHICHDO NOT MEET EGRESS | | | REQUIREMENTS AND ARE LESS THAN 51" IN HEIGHT WITH A | | | SINGLE HUNG WINDOW PROPOSED, NOTE EXISTING CONDITIONS | | | (TYPE OF WINDOW) AND OPENING SIZE FOR BEDROOMS, FBC | | | R310, FBC EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED | | | BY MORE THAN 5%. | | | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT: | | | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | | - AWNING, CASEMENT, SINGLE HUNG? | | | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | | WINDOW IS FULLY OPEN. | | | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | | | | | 2015-02-12 12:14:46 | ROUTED TO BUILD <5K |
|