| Date |
Text |
| 2015-02-10 07:06:50 | PLAN REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY MECHANICAL |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND |
| | SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN |
| | AN EQUIPMENT SCHEDULE ON THE REVISED MECHANICAL PLAN |
| | THAT CORRESPONDS WITH THE EQUIPMENT SIZING |
| | CALCULATIONS. |
| | |
| | 2) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT |
| | BEDROOMS. SPECIFY THE SIZE OF THE RETURN AIR TRANSFER |
| | DUCT FROM BEDROOM IN BOTH UNITS. TRANSFER DUCTS MAY |
| | ACHIEVE THIS BY INCREASING THE RETURN TRANSFER 1-1/2 |
| | TIMES THE CROSS SECTIONAL AREA (SQUARE INCHES) OF THE |
| | SUPPLY DUCT ENTERING THE ROOM OR SPACE IT IS SERVING |
| | AND THE DOOR HAVING AT LEAST AN UNRESTRICTED 1 INCH |
| | UNDERCUT TO ACHIEVE PROPER RETURN AIR BALANCE. |
| | |
| | 3) FBC 107.2 SPECIFY ON THE REVISED MECHANICAL PLAN HOW |
| | THE RETURN AIR WILL ENTER THE CLOSET THAT CONTAINS THE |
| | AIR HANDLER. SHOW THE SIZE OF THE THROUGH THE WALL |
| | RETURN AIR GRILL OR SPECIFY THAT THE CLOSET DOORS ARE |
| | TO BE LOUVERED ON THE MECHANICAL PLANS. |
| | |
| | NOTE: THESE PLANS HAVE BEEN DESIGNED, SIGNED, SEALED |
| | AND DATED BY A FLORIDA LICENSED ENGINEER AND ARE |
| | REQUIRED TO COMPLY WITH FLORIDA STATUTES 471. |
| | |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | |