| 2015-03-13 16:08:25 | RESIDENTIAL (R3) GARAGE ALTERATION, BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- CONVERTING GARAGE TO LIVING SPACE: BRING PLANS TO |
| | PALM BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES |
| | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF |
| | PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY |
| | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| | CODE. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION AND SEC. 101.5 |
| | OF 2010 FBC-EXISTING BUILDING. |
| | |
| | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 OF CITY |
| | AMENDMENTS TO FBC. REVISE VALUATION AS REQUIRED. OR |
| | PROVIDE COPY OF SIGNED CONTRACT FOR THE CONSTRUCTION |
| | AND DESIGN PROFESSIONAL FEES. |
| | |
| | 4- THESE PLANS ARE NOT TO BE USED FOR CONSTRUCTION. SEE |
| | STATEMENT AT THE BOTTOM LEFT OF SHEET A.01: |
| | "PRELIMINARY SET - NOT FOR CONSTRUCTION". PROVIDE PLANS |
| | THAT ARE READY FOR BUILDING PERMITS AND CONSTRUCTION. |
| | SEC. 107.2.1 CITY AMENDMENTS. TO FBC. |
| | |
| | 5- ARCHITECT TO SPECIFY ALTERATION LEVEL TYPE AS |
| | REQUIRED BY SEC. 401.4 OF 2010 FBC EXISTING BUILDING. |
| | |
| | 6- ARCHITECT TO PROVIDE INFORMATION SHOWING COMPLIANCE |
| | WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) ALL WINDOW TYPES SPECIFIED ON PLANS. |
| | |
| | B) PRECAST LINTELS SPECIFIED ON NEW WINDOW/DOOR BUCK |
| | DETAIL. |
| | |
| | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 9- EXTERIOR BLOCK WALL SECTION 1/A.01: |
| | A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING |
| | COMPLIANCE WITH R-11 INSULATION ON A CONCRETE BLOCK |
| | WALL AS SPECIFIED ON THE WALL SECTION. NOTE: COORDINATE |
| | WITH THE ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | B) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R302.11 OF |
| | 2010 FBC-RESIDENTIAL. |
| | |
| | 10- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE |
| | WITH THE HEATING REQUIREMENTS OF SEC. R303.8 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | |