| 2015-02-19 15:01:06 | BUILDING PLAN REVIEW |
| | PERMIT: 15010989 |
| | ADD: 627 NATHAN HILL RD |
| | CONT: CASAVECCHIA MARBLE & SERVICE |
| | E-MAIL: [email protected] |
| | TEL: (561)722-3696 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: THURS. FEB. 19/ 2015 |
| | ACTION: DENIED |
| | |
| | 1A) THE SCOPE OF THIS PERMIT NEEDS TO BE BETTER |
| | DEFINED, IT APPEARS THE RENEWED WINDOW PERMIT 14120483 |
| | HAS FAILED THE INSPCTION FOR ROTTEN WOOD BUCKS AND |
| | FRAMING. THESE ITEMS SHOULD BE A REVISION THAT TIES |
| | BACK TO PERMIT 14120483. ANY FRAMING THAT NEEDS TO BE |
| | REPLACED, PROVIDE DETAILS WHERE THESE LOCATIONS OCCUR, |
| | THE SAME WITH THE MULLIONS THAT HAVE EXPOSED CLIPS TOP |
| | AND BOTTOM. IF THE WINDOW FRAMING IS TO THE POINT THAT |
| | IT NEEDS TO BE REPLACED ALSO SHOW THE STRAPPING OF THE |
| | HEADER, JACKS AND FULL LENGTH STUDS. DEPENDING ON THE |
| | WIDTH OF THE OPENINGS THE JACKS/ CRIPPLES AND FULL |
| | LENGHT STUDS MAY REQUIRE DOUBLING. |
| | |
| | 1B) THE OTHER ISSUE IS WITH THE WOOD BUCKS, IT IS NOT |
| | KNOWN IF THE BUCKS ARE BEING APPLIED TO WOOD FRAMING OR |
| | TO CBS CONSTRUCTION. THE BUCKS FOR BOTH WINDOWS AND |
| | DOORS IN CBS CONSTRUCTION NEEDS TO SHOW COMPLIANCE WITH |
| | FBC-B |
| | 1715.5.4.2 MASONRY, CONCRETE OR OTHER STRUCTURAL |
| | SUBSTRATE. |
| | WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 11/2 |
| | INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE |
| | ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR |
| | SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER?S |
| | PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE |
| | SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE |
| | OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS |
| | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE |
| | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT |
| | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE |
| | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE |
| | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF |
| | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED |
| | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE |
| | ROUGH OPENING SUBSTRATE. |
| | |
| | 2) WHAT APPEARS TO BE COVERED UNDER THIS PERMIT: |
| | (3) NEW HURRICANE PANELS TO COVER DOORS IDENTIFIED AS |
| | 5, 8 & 9 NOTE THERE IS NO FLORIDA COVERSHEET ON THE |
| | SHUTTER REPORT. |
| | (3) UNKNOWN, IF PART OF THIS PERMIT, DOORS 5,8 & 9 |
| | STATE THEY ARE EXISTING, THERE IS A NOA 04-0611.02 FOR |
| | OUTSWING PATIO DOORS, EXPIRED . |
| | (1) KITCHEN WINDOW A SEPARATE FL. REPORT # 2284 WAS |
| | SUBMITTED. |
| | ON THE SUBMITTED FLOOR PLAN THAT IS COLOR CODED, PLEASE |
| | PROVIDE THE PRODUCT APPROVAL NUMBER BY EACH OF THE |
| | COLLORS TO IDENTIFY THE LOCATION WITHIN THE STUCTURE. |
| | |
| | 3) PLEASE SEE THE PRODUCT APPROVAL FOR THE 13 WINDOWS, |
| | NOA 03-1211.01W03-105 SHEET 1 OF 5, INDICATES WINDOWS |
| | IN SERIES, (SIDE BY SIDE) WILL REQUIRE APPROVED |
| | MULLIONS, NOA 02-0227.01 IDENTIFY THE MULLION CLIP |
| | INSTALLED, ON SHEET 3 OF 4 IDENTIFY WHICH LOAD CHART BY |
| | ANCHOR TYPE INSTALLED AND ASSOCIATED PRESSURES AND |
| | TRIBUTARY WIDTHS, |
| | |
| | 4) FOR THE NEW SINGLE HUNG KITCHEN WINDOW FL # 2284 |
| | CIRCLE THE TYPE OF APPLICATION TO BE USEDFOR |
| | INSTALATION. |
| | |
| | 5) STORM SHUTTER REPORT WILL NEED TO FILE OUT A SHUTTER |
| | SCHEDULE WITH THE FOLLOWING INFORMATION: A COMPLETE |
| | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| | WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE |
| | PLAN REVIEW AND PERMIT ISSUANCE. A SAMPLE SHUTTER |
| | SCHEDULE CAN BE PICKED UP FROM THE BUILDING DEPARTMENT. |
| | |
| | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |