| 2015-02-05 10:18:18 | BUILDING PLAN REVIEW |
| | PERMIT: 15010981 |
| | ADD: 720 S. SAPODILLA AVE. # 510 |
| | CONT: ABACOA CONSTRUCTION |
| | TEL: (561) 633-8346 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. FEB. 04/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) CONTRACTOR SUBMITTED CONTRACT VALUE FOR THE SCOPE OF |
| | WORK. |
| | |
| | 2) AT MEET AND GREET STATION REVIEW NEW PROPOSED |
| | FLOORING UNDER LAYMENT, THE COMPANY HAD A REPORT TO THE |
| | WRONG STANDARD E-90, NOT THE E-492 FOR SOUND. |
| | CONTRACTOR WILL LOOK FOR A NEW PRODUCT. NOTE THE |
| | BUILDING HAS A 6 INCH CONCRETE SLAB, NOT A 8 INCH WHICH |
| | MOST SOUND REPORTS USE WITH A DROPPED CEILING. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| 2015-02-03 08:07:24 | BUILDING PLAN REVIEW |
| | PERMIT: 15010981 |
| | ADD: 720 S. SAPODILLA AVE. # 510 |
| | CONT: ABACOA CONSTRUCTION |
| | TEL: (561) 633-8346 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. FEB. 03/ 2015 |
| | ACTION: DENIED |
| | |
| | THIS BUILDING WAS BUILT UNDER THE 1997 SSBC BUILDING |
| | TYPE V-1HR= 2010 FBC-B TYPE IIIA |
| | |
| | 1) PLEASE PROVIDE WHAT TYPE OF FLOOR FINISH WILL BE |
| | APPLIED OVER THIS TYPE OF FLOOR INSULATION. 2010 FBC-B |
| | 804.1. |
| | |
| | 2) THE SUBMITTED SAM 3 90 SOUND CONTROL REPORT DOES NOT |
| | INCLUDE ANY FLAME SPREAD NOR SMOKE DEVELOPMENT TESTING |
| | RESULTS. PLEASE PROVIDE COMPLIANCE WITH: |
| | 2010 FBC-B 719.2 CONCEALED INSTALLATION. INSULATING |
| | MATERIALS, WHERE CONCEALED AS INSTALLED IN BUILDINGS OF |
| | ANY TYPE OF CONSTRUCTION, SHALL HAVE A FLAME SPREAD |
| | INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX |
| | OF NOT MORE THAN 450. WHERE A FLAME SPREAD INDEX OR A |
| | SMOKE-DEVELOPED INDEX IS SPECIFIED IN THIS SECTION, |
| | SUCH INDEX SHALL BE DETERMINED IN ACCORDANCE WITH ASTM |
| | E 84 OR UL 723. |
| | |
| | 3) THE VALUATION IS FOR THE WHOLE JOB, NOT JUST THE |
| | INSULATION, PLEASE PROVIDE A CONTRACT WITH THE TOTAL |
| | CONTRACT VALUE OF THE PREJECT. |
| | W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| | ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| | AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| | A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| | APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |