2015-08-11 09:29:38BUILDING PLAN REVIEW
 PERMIT: 15010897
 ADD: 4720 BROADWAY
 CONT: ROBLING ARCHITECTURE
 TEL: (561)649-6705
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 4TH REVIEW
 DATE: TUES. AUG. 11/ 2015
  
 ACTION: BUILDING PROVISO/ DEFERRED SUBMITTAL
  
 ARCHITECT DAMON ROBLING SENT E-MAIL 08/10/15 04:04 PM
 ASKING IF THE PRODUCT APPROVALS CAN BE A PROVISO/
 DEFERRED SUBMITTAL.
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION,
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 1) ROOFING REPORT: FL 13464-RO ROOFING GAF MODIFIED FL
 13464- R0 THE ROOFING SUB-SYSTEMS TO BE APPLIED HAS NOT
 BEEN IDENTIFIED NOR THE ASSOCIATED PRESSURES. SEE
 APPENDIX SHEET 2 OF 13 NOTE 8 REQUIRES ENHANCED
 FASTENING BY A QUALIFIED DESIGN PROFESSIONAL.
 THE DESIGNER OF RECORD ON SHEET A1.0 HAS LISTED TABLE #
 1 ON PLANS WHICH ALLOWS THE FOLLOWING PRODUCTS (TABLE
 1) MAKE UP THE SUBJECT SYSTEMS. NOTE TABLES 2A, 2B & 2C
 ARE STEEL DECKS WITH INSULATION NONE OF THE SUB-SYSTEMS
 HAVE BEEN IDENTIFIED FOR INSTALLATION.
  
 2) FROM 3RD REVIEW: SHEET A7.0 FOR EXTERIOR FINISHES
 INDICATES THE USE OF REYNOBOND ACM PANELS FOR THE
 EXTERIOR FINISH OF THE BUILDING. NO PRODUCT APPROVALS
 WERE SUBMITTED FOR THIS PRODUCT. 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(C) PANEL WALLS: ACM PANELS/ AND OR MCM PANELS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  