Plan Review Notes
Plan Review Notes For Permit 15010897
Permit Number 15010897
Review Stop B
Sequence Number 3
Notes
Date Text
2015-08-10 07:36:592010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RDD REVIEW
 DATE: MON. AUG. 10/ 2015
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) PRODUCT APPROVALS.
  
 2A) 3RD REQUEST. GAF MODIFIED FL 13464- R0 THE ROOFING
 SUB-SYSTEMS TO BE APPLIED HAS NOT BEEN IDENTIFIED NOR
 THE ASSOCIATED PRESSURES. SEE APPENDIX SHEET 2 OF 13
 NOTE 8 REQUIRES ENHANCED FASTENING BY A QUALIFIED
 DESIGN PROFESSIONAL.
 THE DESIGNER OF RECORD ON SHEET A1.0 HAS LISTED TABLE #
 1 ON PLANS WHICH ALLOWS THE FOLOWING PRODUCTS (TABLE 1)
 MAKE UP THE SUBJECT SYSTEMS. NOTE TABLES 2A, 2B & 2C
 ARE STEEL DECKS WITH INSULATION NONE OF THE SUB-SYSTEMS
 HAVE BEEN IDENTIFIED FOR INSTALATION. THE DESIGNER OF
 RECORD HAS NOT INDICATED TO BE PICKED BY ROOFING
 CONTRACTOR AND REVIEWED BY THE DESIGNER OF RECORD
 BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT. HAS NOT
 INDICATED THIS TO BE A DEFERRED SUBMITTAL.
  
 3-5) COMPLIED.
  
 6A) NEW COMMENT. SHEET A7.0 FOR EXTERIOR FINISHES
 INDICATES THE USE OF REYNOBOND ACM PANELS FOR THE
 EXTERIOR FINISH OF THE BUILDING. NO PRODUCT APPROVALS
 WERE SUBMITTED FOR THIS PRODUCT. 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(C) PANEL WALLS: ACM PANELS/ AND OR MCM PANELS
  
 6B) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]