2015-01-30 11:26:381) SHT.A1.0 - TOILET ROOMS ARE SHOWN AS 6 '- 8 3/4" IN
 WIDTH.THE ROOMS ARE NOT WIDE ENOUGH TO COMPLY WITH FAC
 604.3.1 AND THE FPC SEC. 405.3.1. THE MINIMUM WIDTH IS
 85" IF BUILT PERFECT OR 86" FOR CONSTRUCTION
 TOLERANCES.
 2) SUBMIT AN EQUIPMENT SCHEDULE FOR THE FOOD OPERATION.
 WPB AMEND. TO 2010 FBC SEC.107.2.1.
 3) SHT.A4.0 - THE REQUIRED CLEAR FLOOR SPACEDIMENSIONS
 FOR THE PLUMBING FIXTURES DOES NOT CORRELATE WITH THE
 WRITTEN DIMENSIONS; WATER CLOSET NEEDS 60 INCHES IN
 WIDTH, 30 INCHES FOR THE LAVATORY EQUALS 90 INCHES
 MINIMUM. THE PLAN SHOWS 80 3/4 ". CLARIFY.
 4) SHT. A.6 - SHOW THE MOUNTING HEIGHT FOR ALL TOILET
 ROOM ACCESSORIES. ALL ACCESSORIES SHALL COMPLY WITH THE
 2010 FL. ACCESS. CODE.
 5) SHT. A6.0 - SHOW THE HEIGHT DIMENSIONS OF ALL
 FIXTURES FROM THE FINISH FLOOR.COMPLY W/2010 FAC
 CHAPTER 306 FOR KNEE & TOE CLEARANCES AND CHAPTER 6 FOR
 PLUMBING ELEMENTS.
 6) SHT. P.1 - SIZE ALL SECTIONS OF THE WASTE STACKS &
 VENT STACKS, WPB AMEND.TO 2010 FBC SEC.107.2.1.
 7) SHT. P-1 - CLEANOUTS ARE REQD. IN THE BASE OF THE
 STACKS PER 2010 FPC SEC.708.3.4.
 8) SHT.P-1 - RISER DIAGRAM SHOWS A DRY VENT ON FIXTURE
 FD-2 AT DRIVE-THRU. DRY VENTS TO CONNECT ABOVE
 CENTERLINE OF DRAIN PIPE. FPC SEC.905.3.
 9) FLOOR DRAINS NOT RECEIVING THE DISCHARGE FROM
 INDIRECT WASTES SHALL BE PROVIDED WITH TRAP PRIMERS PER
 FPC SEC.1002.4.
 10) SHT. P-2 - HOSE BIBBS SHALL BE EQUIPPED WITH
 SHUTOFF VALVES PER FPC SEC.606.2.
 11) ALL BEVERAGE LINWS SHALL BE EQUIPPED W/BACKFLOW
 PREVENTERS COMPLYING WITH FPC SEC.608.16.1, ASSE 1022.
 NON-CARBONATED AND COFFEE BEVERAGE DISPENSERS SHALL
 COMPLY WITH FPC SEC.608.16.10, ASSE 1022.
 12) APPROVAL OF THE PLANS IS REQUIRED BY THE DEPT. OF
 BUSINESS & PROFESSIONAL REGULATION, DIVISION OF HOTEL &
 RESTAURANTS.
  