| 2015-02-25 07:09:51 | BUILDING PLAN REVIEW |
| | PERMIT: 15010897 |
| | ADD: 4720 BROADWAY |
| | CONT: ROBLING ARCHITECTURE |
| | TEL: (561)649-6705 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MAY 11, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: WED. FEB. 20-25 |
| | ACTION: DENIED |
| | |
| | 1) SHEET T1.0 BUILDING CODE CLASSIFICATION: |
| | 1A) LIST (1) EXIT FOR 50 SEATS TOTAL PLEASE SEE THE |
| | 2010 FBC-B TABLE 1015.1 ONE EXIT UNDER THE MERCANTILE |
| | OCCUPANCY IS MAXIMUM AT 49 OCCUPANTS. |
| | 1B) PLEASE NOTE UNDER APPLICABLE CODES THIS PLAN IS TO |
| | BE BUILT IN THE VILLAGE OF NORTH PALM BEACH. |
| | |
| | 2) THERE IS A COVERSHEET LISTING PRODUCT APPROVALS, |
| | THERE IS NO HEADER, TITLE BLOCK FROM A CONTRACTOR NOR |
| | THE DESIGNER, NO SHOP DRAWING STAMP OF APPROVAL, NOR |
| | SIGNATURE OF THE DESIGNER OF RECORD INDICATING THEY |
| | WERE REVIEWED AND CODE COMPLIANT. 2010 FBC 107.3.4.1 |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED |
| | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 2A) KAWNEER OUTSWING STOREFRONT DOORS NOA 11-1013.03 |
| | TECHNICAL SHEETS SUBMITTED 8 1/2 X 11 SIZED FOR 8 1/2 X |
| | 14 CUT OFF 1/3 OF SHEET. |
| | 2B) KAWNEER STOREFRONT NOA 11-0908.10 TECHNICAL SHEETS |
| | SUBMITTED 8 1/2 X 11 SIZED FOR 8 1/2 X 14 CUT OFF 1/3 |
| | OF SHEET. |
| | 2C) TIA BAR TC-5 SERIES ROOF CURBS NOA-0828.02 |
| | TECHNICAL SHEETS SUBMITTED 8 1/2 X 11 SIZED FOR 8 1/2 X |
| | 14 CUT OFF 1/3 OF SHEET. |
| | 2D) MIAMI TECH ALUMINUM A/C STANDS 13-1017.09 TECHNICAL |
| | SHEETS SUBMITTED 8 1/2 X 11 SIZED FOR 8 1/2 X 14 CUT |
| | OFF 1/3 OF SHEET. |
| | FLEMING-BARON EXTERIOR DOOR FL 14237-R1 NO TECHNICAL |
| | SHEETS SUBMITTED. |
| | GAF MODIFIED FL 13464- R0 THE ROOFING SUB-SYSTEMSTO BE |
| | APPLIED NOT IDENTIFIED NOR THE ASSOCIATED PRESSURES. |
| | |
| | 3) SHEET S-2 THE WIND DESIGN PRESSURES INDICATE A B |
| | EXPOSURE PLEASE REVIEW WHEN WITHIN 1400 FT OF THE |
| | INTERCOASTAL FOR THIS LOCATION TO BE CONSIDERED A B |
| | EXPOSURE THE JOBSITE LOCATION WOULD NEED TO BE A |
| | MINIMUM 2,600 FT AWAY FROM THE INTERCOASTAL. FBC-B |
| | 1609.4.2 SURFACE ROUGHNESS CATEGORIES. BECAUSE THE |
| | EXPOSURE C CATEGORY HAS MULTIPLIERS WITH ITS HEIGHT THE |
| | PRESSURES PROVIDED ARE LOW. TABLE 1609.7(2). |
| | |
| | 4A) SHEET S-2 DETAIL # 3 SHOWS A NEW CONCRETE DECK- THE |
| | PLANS DO NOT PROVIDE TYPE OR AMOUNT OF RE-INFORCING |
| | STEEL OR CONCRETE MIX? 107.2.1.3 ADDITIONAL INFORMATION |
| | IS REQUIRED. |
| | |
| | 4B) DETAIL #2 SHOWS A NEW ROOF DECK NOTE SEE PLANS |
| | AGAIN NO DETAIL FOR RE-INFORCING STEEL OR CONCRETE MIX, |
| | NEW ROOF PITCH W/ VERMICULITE? |
| | |
| | 5) SHEET A8.0 SECTIONS 2,3 & 4 ARE THESE SECTIONS FOR |
| | THE SIGN OR BUILT OUT WALL SECTIONS? NO ATTACHMENT, |
| | FRAMING OR MATERIALS FOR THE SURFACE FINISH? |
| | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |