| 2015-02-07 08:34:06 | BUILDING PLAN REVIEW |
| | PERMIT: 15010836 |
| | ADD: 5300 GEORGIA AVE. |
| | CONT: H. CANO INC. |
| | TEL: (561)586-2212 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. FEB. 07/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THE CONTRACTOR HAS MIS-REPRESENTED THE SCOPE OF WORK |
| | UNDER THIS PROJECT. THERE ARE CURRENTLY 4 CODE CASES |
| | GOING ANGAINST THIS PROPERTY. SOFT HOLDS FLAG THIS |
| | PREOPERTY, THE PHOTOGRAPHS FROM THE SITE VISIT FROM THE |
| | CODE, FIRE AND BUILDING INSPECTORS SHOW VARIOUS |
| | VIOLATIONS FOR THE INTERIOR AS WELL AS ON THE EXTERIOR |
| | OF THE PROPERTY. |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1. CONSTRUCTION |
| | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE |
| | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED |
| | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. |
| | INSUFFIENT INFORMATION PROVIDED FOR A MINIMUM PLAN |
| | REVIEW CRITERIA FOR BUILDINGS: |
| | |
| | 107.3.5.1 COMMERCIAL BUILDINGS: THE EXAMINATION OF THE |
| | DOCUMENTS BY THE BUILDING OFFICIAL SHALL INCLUDE THE |
| | FOLLOWING MINIMUM CRITERIA |
| | 107.3.5.1.1 BUILDING 1.1) FLOOR PLAN FOR THE TOTAL AREA |
| | INSIDE THE BUILDING, DESIGNATE AREAS OF WORK AND AREAS |
| | WHERE CHANGE OF OCCUPANCY HAS OCURRED, ( COOKING AREAS |
| | & NEW BUSINESS OCCUPANCIES) |
| | |
| | 1.2) OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| | SHALL BE DETERMINED. AMOUNTS OF BOTTLED GASSES STORED |
| | ON THE INTERIOR AND OR EXTERIOR |
| | OF THE BUILDING. |
| | |
| | 1.3) MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED |
| | (SEE TABLE 503). |
| | |
| | 1.4) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| | OCCUPANCY LOAD |
| | GROSS |
| | NET |
| | MEANS OF EGRESS |
| | EXIT ACCESS |
| | EXIT |
| | EXIT DISCHARGE |
| | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION |
| | DOORS |
| | |
| | 1.5) ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE |
| | FOLLOWING: |
| | SITE REQUIREMENTS |
| | ACCESSIBLE ROUTE |
| | VERTICAL ACCESSIBILITY |
| | TOILET AND BATHING FACILITIES |
| | DRINKING FOUNTAINS |
| | EQUIPMENT |
| | SPECIAL OCCUPANCY REQUIREMENTS |
| | |
| | 1.6) INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING: |
| | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) |
| | LIGHT AND VENTILATION |
| | SANITATION |
| | |
| | 2) THE DESIGNER OF RECORD HAS NOT DECLARED TO WHICH |
| | METHOD THEY HAVE DESIGNED UNDER THE 2010 FBC-EISTING |
| | BUILDING CODE: |
| | |
| | EXST. BLDG. CODE101.4.2 BUILDINGS PREVIOUSLY OCCUPIED. |
| | THE LEGAL OCCUPANCY OF ANY BUILDING EXISTING ON THE |
| | DATE OF ADOPTION OF THIS CODE SHALL BE PERMITTED TO |
| | CONTINUE WITHOUT CHANGE, EXCEPT AS IS SPECIFICALLY |
| | COVERED IN THIS CODE, THE FLORIDA FIRE PREVENTION CODE, |
| | OR AS IS DEEMED NECESSARY BY THE CODE OFFICIAL FOR THE |
| | GENERAL SAFETY AND WELFARE OF THE OCCUPANTS AND THE |
| | PUBLIC. |
| | |
| | EXST. BLDG. CODE 101.5 COMPLIANCE METHODS. THE REPAIR, |
| | ALTERATION, CHANGE OF OCCUPANCY, ADDITION OR RELOCATION |
| | OF ALL EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE |
| | METHODS LISTED IN SECTIONS 101.5.1 THROUGH 101.5.3 AS |
| | SELECTED BY THE APPLICANT. |
| | |
| | 3) FOR THE TRUE AMOUNT OF WORK TO MAKE THIS BUILDING |
| | CODE COMPLIANT, AND WORK COMPLETED WITH OUT A PERMIT, |
| | AND THE CHANGE OF OCCUPANCIES THAT HAS OCCURRED, THE |
| | VALUE OF WORK IS TO LOW; |
| | |
| | 3A) PERMIT FEES TO BE UPGRADED TO REFLECT THE AMOUNT OF |
| | WORK TO BE COMPLETED TO RESOLVE THE CODE CASES : W P B |
| | ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. ON |
| | BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, AND |
| | PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, A |
| | FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| | APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 3B) THE VALUE OF WORK WILL ACCEDE $25,000.00 DOLLORS |
| | THAT WILL MAKE IT NECCESSARY FOR A DESIGN PROFESSIONAL |
| | TO DESIGN THE PLANS AND NOT A CONTRACTOR. FL. S. |
| | 481.229(C). |
| | |
| | 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | |
| | |
| | |
| | |