| Plan Review Notes For Permit 15010607 |
| Permit Number |
15010607 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2015-04-10 14:37:52 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- FLAT ROOF: ENGINEER TO REVISE THE RAS 117 | | | CALCULATIONS. NAIL SPACING SHOWN FOR ROOF ZONE #1 | | | DOESN'T MATCH NAIL SPACING SHOWN ON NOA 13-1022.15. | | | REVISE ALL CALCULATIONS AS REQUIRED. SEE SEC. 8.1 OF | | | RAS 117. | | | 2- REVISE ALL NOTES ON SHEET SP-1. THIS IS A NEW SINGLE | | | FAMILY RESIDENCE NOT REMODELING. EXISTING HOUSE WILL BE | | | COMPLETELY DEMOLISHED. | | | 3- REVISE TYP. WALL SECTION 1/A-2. ATTIC VENTED OR | | | ICYNENE INSULATION. COORDINATE WITH THE ENERGY | | | CALCULATIONS. | | | 4- PROVIDE ICYNENE ICC EVALUATION REPORT (2 COPIES). | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR ALL SIMPSON | | | STRUCTURAL CONNECTORS SPECIFIED ON ALL PLANS AND | | | DETAILS OR SPECIFY THE FLORIDA PRODUCT APPROVAL NUMBER | | | NEXT TO THE SPECIFIED CONNECTOR. ALSO, UPDATE THE | | | FLORIDA PRODUCT APPROVAL NUMBERS SPECIFIED ON CONNECTOR | | | SCHEDULE ON SHEET S-2. THEY DON'T CORRESPOND TO THE | | | 2010 FBC CODE VERSION. | | | |
|