| Plan Review Notes For Permit 15010518 |
| Permit Number |
15010518 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2015-01-28 12:48:02 | RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROFLEX 90 UNDERLAYMENT: PROVIDE COPIES OF THE SOUND | | | TRANSMISSION CLASS (STC) TEST DONE IN ACCORDANCE WITH | | | ASTM E 90 AND IMPACT INSULATION CLASS (IIC) TESTS DONE | | | IN ACCORDANCE TO ASTM E 492. SEC. 1207.2 AND 1207.3 OF | | | 2010 FBC-BUILDING. | | | | | | NOTE: ASSEMBLY TESTED NEED TO MATCH CONDITIONS OF | | | PROPOSED FLOOR ASSEMBLY. THE TEST REPORTS I HAVE SEEN | | | ARE FOR 8" CONCRETE SLAB SUSPENDED ACOUSTICAL CEILING. | | | ACCORDING TO CITY RECORDS THE FLOOR BETWEEN APARTMENTS | | | AT THIS ADDRESS IS 7" CONCRETE SLAB WITH NO SUSPENDED | | | CEILING ASSEMBLY. THIS IS THE KIND OF ASSEMBLY THE | | | TESTING IS REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|