2015-01-21 15:50:34RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC
  
 1- SOUND TRANSMISSION CLASS (STC) TEST AND IMPACT
 INSULATION CLASS (IIC) TEST SUBMITTED FOR PROFLEX MSC
 90 UNDERLAYMENT IS FOR AN 8" CONCRETE SLAB WITH AN
 ACOUSTICAL SUSPENDED CEILING ASSEMBLY. IF THE FLOOR
 CEILING ASSEMBLY IS NOT AN 8" CONCRETE SLAB WITH A
 SUSPENDED CEILING, THEN IT CAN NOT BE USED BECAUSE THE
 UNDERLAYMENT NEED TO BE INSTALLED IN FLOOR ASSEMBLY AS
 TESTED. SEC. 1207.2 AND SEC. 1207.3 OF 2010
 FBC-BUILDING. NOTE: BASED ON PRELIMINARY RESEARCH, THE
 CITY RECORDS SHOW BUILDING SECTIONS WITH 5 1/2"
 CONCRETE SLABS BETWEEN APARTMENTS. NEED TO PROVIDE
 COPIES OF TESTS DONE ON 5 1/2" CONCRETE SLABS WITH NO
 SUSPENDED CEILINGS IN ORDER TO SHOW COMPLIANCE WITH SEC
 1207.2 AND SEC. 1207.3.
  