| Plan Review Notes For Permit 15010271 |
| Permit Number |
15010271 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-01-20 14:20:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. APPLICATION IS FOR IMPACT WINDOWS, NOA IS FOR NON | | | IMPACT. | | | | | | IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 2. REVISE FLOOR PLAN TO INCLUDE ROOM DESIGNATIONS. | | | | | | 3. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION FOR BEDROOMS IF WINDOW HEIGHT IS LESS THAN | | | 51?; FBC R310, FBC EB 604.1. THE CLEAR OPENING CANNOT | | | BE REDUCED BY MORE THAN 5%: | | | | | | REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW | | | IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG? | | | | | | REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING | | | DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH | | | EXISTS WHEN THE WINDOW IS FULLY OPEN. | | | | | | REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING | | | DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE | | | MANUFACTURER | | | | | | | | | |
|