Plan Review Notes
Plan Review Notes For Permit 15010129
Permit Number 15010129
Review Stop P
Sequence Number 2
Notes
Date Text
2015-01-30 05:34:211) SUBMIT 2 COPIES OF THE MANUFACTURER'S
 SPECS/INSTALLATION MANUAL FOR THE TANKLESS WATER HEATER
 FOR REVIEW. WPB AMEND. TO 2010 FBC SEC.107.2.1.2ND
 REQUEST. THERE WERE NO SPEC/MANUAL ATTACHED.
 2) SHOW THE REQUIRED KNEE & TOE CLEARANCE DIMENSIONS
 FOR THE LAVATORIES AND THE DRINKING FOUNTAINS ON SHTS.
 A-4.1 & A-4.2. COMPLY W/ FL. ACC. CODE SEC. 306. 2ND
 REQUEST.
 3) SHT. A-4.1 - ELEVATIONS # 3 & # 4 - TYPO -THERE ARE
 IDENTIFICATION ARROWS AND ITEM NAMES ON THE PLANS
 POINTING TO NOTHING. WPB AMEND. TO 2010 FBC
 SEC.107.2.1.
 4) SHT.A-4.2 - RESTROOM #122 IS CALLED OUT AS A UNISEX
 RESTROOM. PER SEC.403.5.2 & 403.5.3 OF 2010 FPC, A
 UNISEX TOILET ROOM SHALL INCLUDE ONLY ONE WATER CLOSET
 AND ONE LAVATORY (AND ONE URINAL PER EXCEPTION). UNISEX
 BATHING ROOMS SHALL ALSO INCLUDE ONE WATER CLOSET AND
 ONE LAVATORY. THIS RESTROOM DOES NOT MEET THE
 DEFINITION OF A UNISEX RESTROOM. COMPLY WITH THE STATED
 PUMBING CODE SECTIONS.
 4) SHT. A-4.2 - SHOW THE WIDTH OF THE ACCESSIBLE SHOWER
 IN ROOM # 122. MINIMUM WIDTH SHALL BE 30 INCHES. FAC
 SEC.608.2.2. 2ND REQUEST.
 5) SHT.A-4.2 - ELEVATION #4 R.R. 122- TYPO - SHOWS BOTH
 URINALS AS ADA ACCESSIBLE BUT ONE DOES NOT COMPLY.MAX.
 HEIGHT TO THE RIM SHALL BE 17 INCHES. FAC SEC.605.2.
 6) SHT.A-4.2 - THE ACCESSIBLE SHOWER SHALL HAVE A
 MINIMUM 60 INCH WIDE ENTRY ON THE FACE OF THE SHOWER
 COMPARTMENT PER THE FAC SEC.608.2.2. THE LAVATORY
 APPEARS TO ENCROACH IN THIS SPACE. CLARIFY.
 7) SHT.A-4.2 - THE ACCESSIBLE SHOWER SHALL HAVE GRAB
 BARS PROVIDED ON THREE SIDES IN ROLL IN SHOWERS WITHOUT
 SHEETS PER THE FAC SEC.608.3.2. SPACING FROM ADJACENT
 WALLS SHALL COMPLY WITH FAC SEC.608.3.2.
 8) SHT. P0.1 - SIZE ALL SECTIONS OF THE VENTING SYSTEM
 ON THE SANITARY RISER. WPB AMEND. TO 2010 FBC
 SEC.107.2.1.2ND REQUEST. YOUR RESPONSE REFERS TO THE
 ARCHITECTURAL PAGES WHICH ARE ELEVATION DETAILS.??
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692