| Plan Review Notes For Permit 14120907 |
| Permit Number |
14120907 |
|
| Review Stop |
E |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2015-07-13 20:41:46 | ELECTRICAL PROVISO FOR PERMIT 14120907 | | | | | | HEATING AS DESCRIBED ON PLANS IS NOT COMPLIANT | | | CORRECT ACCORDINGLY: | | | R303.8 REQUIRED HEATING. WHEN THE WINTER DESIGN | | | TEMPERATURE IN TABLE R301.2(1) IS BELOW 60?F (16?C), | | | EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING | | | FACILITIES CAPABLE OF MAINTAINING A MINIMUM ROOM | | | TEMPERATURE OF 68?F (20?C) AT A POINT 3 FEET (914 MM) | | | ABOVE THE FLOOR AND 2 FEET (610 MM) FROM EXTERIOR WALLS | | | IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE | | | INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS | | | SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS | | | SECTION. | | | |
|