| 2015-07-05 14:20:02 | ****PROVISO**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | PLAN REVIEW HAS BEEN PASSED WITH REDLINES. | | | | | | THE INSTALLATION SCHEDULE HAS BEEN REVISED AND THE NOA | | | HAS BEEN CIRCLED SO THAT CONTRACTOR CAN SEE WHERE THE | | | INFORMATION WAS OBTAINED. IF CONTRACTOR DOES NOT AGREE | | | WITH THE CHANGES, PLEASE REVISE THE PRODUCT APPROVAL TO | | | INDICATE ANCHORING PROPOSED, REVISE THE INSTALLATION | | | SCHEDULE, AND PROVIDE EXPLANATION FOR THE FOLLOWING: | | | | | | PAGE 10, A DETAIL WITH WOOD SUBSTRATE CIRCLED, BUT IT | | | APPEARS THAT WOOD IS NOT A SUBSTRATE FOR ANY OPENINGS. | | | INSTALLATION SCHEDULE STATED THAT SUBSTRATE IS | | | CONCRETE; MOST CBS STRUCTURES HAVE CONCRETE TOP (FORMED | | | AND POURED TIE BEAM OR LINTEL) AND BLOCK BOTTOM | | | SUBSTRATES. | | | OPENINGS 7 & 8, DUE TO THE SIZE IT APPEARS THAT THEY | | | ARE SLIDING GLASS DOORS. THE FLOOR PLAN IS NOT CLEAR. | | | THESE TWO OPENINGS ARE LIKELY CONCRETE TOP & BOTTOM, | | | BUT I WAS UNABLE TO LOCATE MOUNTING CONNECTION TYPE | | | "D2" ON THE PRODUCT APPROVAL (SEE PAGES 4 & 5 - A, B, C | | | ONLY). | | | | | | | | | | | | |
|