Plan Review Notes
Plan Review Notes For Permit 14120697
Permit Number 14120697
Review Stop E
Sequence Number 3
Notes
Date Text
2015-12-23 14:10:401ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
 PROVISO
  
 230.24 CLEARANCES. OVERHEAD SERVICE CONDUCTORS SHALL
 NOT
 BE READILY ACCESSIBLE AND SHALL COMPLY WITH 230.24(A)
 THROUGH (E) FOR SERVICES NOT OVER 600 VOLTS, NOMINAL.
 (A) ABOVE ROOFS. CONDUCTORS SHALL HAVE A VERTICAL
 CLEARANCE
 OF NOT LESS THAN 2.5 M (8 FT) ABOVE THE ROOF SURFACE.
 THE VERTICAL CLEARANCE ABOVE THE ROOF LEVEL SHALL BE
 MAINTAINED
 FOR A DISTANCE OF NOT LESS THAN 900 MM (3 FT) IN ALL
 DIRECTIONS FROM THE EDGE OF THE ROOF.