| Notes |
| Date |
Text |
| 2015-12-23 14:10:40 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | | | | PROVISO | | | | | | 230.24 CLEARANCES. OVERHEAD SERVICE CONDUCTORS SHALL | | | NOT | | | BE READILY ACCESSIBLE AND SHALL COMPLY WITH 230.24(A) | | | THROUGH (E) FOR SERVICES NOT OVER 600 VOLTS, NOMINAL. | | | (A) ABOVE ROOFS. CONDUCTORS SHALL HAVE A VERTICAL | | | CLEARANCE | | | OF NOT LESS THAN 2.5 M (8 FT) ABOVE THE ROOF SURFACE. | | | THE VERTICAL CLEARANCE ABOVE THE ROOF LEVEL SHALL BE | | | MAINTAINED | | | FOR A DISTANCE OF NOT LESS THAN 900 MM (3 FT) IN ALL | | | DIRECTIONS FROM THE EDGE OF THE ROOF. |
|