2015-09-17 16:15:30RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) TO
 VERIFY IF IMPACT FEES ARE ASSESSED. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 2-PROVIDE DOOR AND WINDOW STRUCTURAL BUCK DETAILS.
 NOTE: BUCK SIZE NEEDS TO PROVIDE FULL SUPPORT TO THE
 DOOR/WINDOW FRAME. SEE SEC. R612.10.2.1 OF 2010
 FBC-RESIDENTIAL.
 ***RESPONSE:
 A) DETAIL 4/A-5 DOESN'T SPECIFY WINDOW BUCK SIZE. NOTE:
 "BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE OF THE
 WINDOW OR DOOR FRAME SUCH THAT FULL SUPPORT OF THE
 FRAME IS PROVIDED". SEE SEC. R612.10.2.1 OF 2010
 FBC-RESIDENTIAL AND PRODUCT APPROVALS SUBMITTED. REVISE
 DETAIL AS REQUIRED.
 B) SIZE OF DOOR BUCK SPECIFIED ON DETAIL 5/A-5 DOESN'T
 PROVIDE DOOR FRAME FULL SUPPORT. NOTE: "BUCKS SHALL
 EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR
 FRAME SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED".
 SEE SEC. R612.10.2.1 OF 2010 FBC-RESIDENTIAL AND
 PRODUCT APPROVALS SUBMITTED. REVISE DETAIL AS REQUIRED.
 AND CLARIFY WHAT'S "2"X4" DOOR METAL BUCK"?. SEE DOOR
 PRODUCT APPROVAL SUBMITTED.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) NEW WINDOWS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER ON SHEET A-3..
 ***RESPONSE:
 (1) FLORIDA PRODUCT APPROVAL FL5455-R6 SUBMITTED SAYS
 "PENDING FBC APPROVAL". NEED APPROVED PRODUCT APPROVAL.
  
 (2) PROVIDE COMPLETE REPORT ONLY SHEETS 1 OF 6 AND 2 OF
 6 WERE SUBMITTED. NEED COMPLETE DRAWINGS.
  
 B) NEW DOOR THAT MEETS THE DESIGN PRESSURES CALCULATED
 BY THE ENGINEER ON SHEET A-3.
 *** RESPONSE:
 PROVIDE COMPLETE DOOR DRAWINGS. ONLY SHEET 1 OF 7 WAS
 SUBMITTED. AND MARK TYPE OF JAMB TO BE USED: WOOD OR
 PVC?.
  
 C) NEW ROOF SYSTEM. NOTE: SHINGLES ARE NOT ALLOWED ON
 1/4 PER 12 PITCH. PROVIDE PRODUCT APPROVAL FOR LOW
 SLOPE ROOF. CLEARLY IDENTIFY ON THE PRODUCT APPROVAL
 WHICH APPROVED ASSEMBLY IS GOING TO BE USED. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 REQUIRED BY SEC. R301 OF 2010 FBC-RESIDENTIAL.
 *** RESPONSE:
 PROVIDE COMPLETE INFORMATION. ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE FL6623-R2 WAS SUBMITTED. AND, NEED
 TO IDENTIFY THE SELECTED ASSEMBLY.
 NOTE: ROOF LIQUID APPLIED ROOF SYSTEM FL6623-R2
 SUBMITTED SHOW ONLY ONE PRODUCT FOR WOOD DECKS. IT'S
 NOA 08-1112.14. THIS NOA EXPIRED ON 01/01/14. THEREFORE
 CAN'T NOT BE USED. NEED TO PROVIDE ANOTHER ROOF PRODUCT
 APPROVAL. KEEP IN MIND THAT IF SELECTED FLAT ROOF
 ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES REQUIRED BY
 R301, THEN SIGNED AND SEALED RAS 117 CALCULATIONS WILL
 BE REQUIRED. ALSO< REVISE DRAWINGS ACCORDING TO FLAT
 ROOF PRODUCT APPROVAL SELECTED.
  
 D) VENTED ALUMINUM SOFFIT NOA 13-0402.02. PROVIDE
 COMPLETE NOA. ONLY THE COVER PAGE AND PAGE 2 OF 3 WAS
 SUBMITTED.
  
 4- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 5- ENERGY CALCULATIONS SUBMITTED:
 A) OWNER/AGENT TO CERTIFY/DATE AT THE BOTTOM OF FORM
 SUBMITTED.
  
 B) REVISE FORM 402-2010. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.:
 (1)ITEM #1 IS INCORRECT. ARE THE CALCULATIONS FOR
 ENTIRE HOUSE OR FOR JUST THE ENCLOSED ADDITION.
  
 (2)ANSWERS FOR ITEMS #6(A), #6(B) AND #10(A) ARE
 INCORRECT. SEE GENERAL INSTRUCTION NOTE #2 ON FIRST
 PAGE OF FORM.
  
 (3) REVISE ITEM #10. SEE GENERAL INSTRUCTION NOTE #2 ON
 FIRST PAGE OF FORM.
  
 (4) COMPLETE ITEM #12. PROVIDE EQUIPMENT SIZING
 CALCULATIONS AS REQUIRED BY SEC. 401.2 AND SEC.
 403.6.1.1 OF 2010 FBC-ENERGY CONSERVATION.
  
 6-PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW GETTING THE R- 9.06 VALUE ON THE FLOOR AS SPECIFIED
 ON THE ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 OF
 2010 FBC-ENERGY CONSERVATION.
 NOTE: ONLY THE R VALUE OF THE INSULATION NEEDS TO BE
 CONSIDERED. SEE NOTE#3 ON SECOND PAGE OF ENERGY
 CALCULATIONS SUBMITTED.
  
 7- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW GETTING THE R-10.06 ON MASONRY WALLS AS SPECIFIED
 ON THE ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 OF
 2010 FBC-ENERGY CONSERVATION.
 NOTE: ONLY THE R VALUE OF THE INSULATION NEEDS TO BE
 CONSIDERED. SEE NOTE#3 ON SECOND PAGE OF ENERGY
 CALCULATIONS SUBMITTED.
  
 8- PROVIDE MANUFACTURER'S SPECIFICATIONS FOR WINDOWS
 U-FACTOR AND SHGC FACTOR SHOWN ON THE ENERGY
 CALCULATIONS. SEC. 103.2.2 AND SEC. 303.1.3 OF 2010
 FBC-ENERGY CONSERVATION.
  
 ***PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]