Plan Review Notes
Plan Review Notes For Permit 14120697
Permit Number 14120697
Review Stop B
Sequence Number 1
Notes
Date Text
2015-01-14 09:10:33RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) TO
 VERIFY IF IMPACT FEES ARE ASSESSED. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES. SEC. 109.3 CITY AMENDMENTS TO FBC.
 UPDATE VALUATION.
  
 3- DESIGNER OF RECORD TO SPECIFY THE COMBINATION OF
 LEVELS OF ALTERATION AS REQUIRED BY SEC. 401.4 OF 2010
 FBC-EXISTING BUILDING.
  
 4- PROVIDE DOOR AND WINDOW STRUCTURAL BUCK DETAILS.
 NOTE: BUCK SIZE NEEDS TO PROVIDE FULL SUPPORT TO THE
 DOOR/WINDOW FRAME. SEE SEC. R612.10.2.1 OF 2010
 FBC-RESIDENTIAL.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) NEW WINDOWS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER ON SHEET A-3..
  
 B) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY
 IDENTIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES.
  
 C) HURRICANE SHUTTERS IF WINDOWS AND DOORS WITH GLAZING
 DON'T HAVE HURRICANE IMPACT GLASS. AND NEED TO PROVIDE
 COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE.
  
 D) NEW DOOR THAT MEETS THE DESIGN PRESSURES CALCULATED
 BY THE ENGINEER ON SHEET A-3.
  
 E) NEW ROOF SYSTEM. NOTE: SHINGLES ARE NOT ALLOWED ON
 1/4 PER 12 PITCH. PROVIDE PRODUCT APPROVAL FOR LOW
 SLOPE ROOF. CLEARLY IDENTIFY ON THE PRODUCT APPROVAL
 WHICH APPROVED ASSEMBLY IS GOING TO BE USED. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 REQUIRED BY SEC. R301 OF 2010 FBC-RESIDENTIAL.
  
 F) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL
 PLANS AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR ENGINEER MAY LIST THE FLORIDA PRODUCT
 APPROVAL NUMBER NEXT TO EACH SPECIFIED CONNECTOR.
  
 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AS SEALING) ALL THE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 7- SECTION B-B ON SHEET A-2:
 A) SHINGLES ARE NOT ALLOWED ON 1/4 PER 12 PITCH. SEE
 SEC. R905.2.2 OF 2010 FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
  
 B) SIZE OF RAFTERS AND BLOCKING SPECIFIED DON'T MATCH
 SIZE SHOWN ON "OPEN SHED ROOF STRUCTURE FRAMING PLAN ON
 SHEET A-4. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS.
  
 C) PROVIDE COMPLETE SPECIFICATIONS AND DETAILS FOR THE
 UNDER-FLOOR SPACE SHOWN. SPECIFY VENTILATION AND ACCESS
 AS REQUIRED BY SEC. R408 OF 2010 FBC-RESIDENTIAL.
  
 8- SECTION A-A ON SHEET A-2:
 A) WINDOW SHOWN ON THIS SECTION DOESN'T MATCH WINDOW
 SHOWN ON NEW NORTH ELEVATION ON SHEET A-3: REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) SPECIFY SIZE OF EXISTING FOOTING WHERE NEW CONCRETE
 BLOCK WALL IS GOING TO BE ERECTED. SEC. R401.2 OF 2010
 FBC-RESIDENTIAL.
  
 C) PROVIDE SPECIFICATIONS SHOWING COMPLIANCE FOR THE
 PROTECTION OF THE "NEW 1" X 3" STRIPPING" SPECIFIED FOR
 THE NEW WALL. SEC. R317.1(7) OF 2010 FBC-RESIDENTIAL.
  
 9- SECTION C-C ON SHEET A-4:
 A) SECTION DETAIL IS TOO SMALL FOR FILING PURPOSES.
 PROVIDE A LARGER SCALE DRAWING WITH LARGER LETTERING AS
 REQUIRED BY SEC. 107.2.1.4 CITY AMENDMENTS.
  
 B) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR NEW
 SOFFIT SHOWING COMPLIANCE WITH SEC. R703.1.3 OF 2010
 FBC-RESIDENTIAL.
  
 C) PROVIDE DETAILS AND SPECIFICATIONS FOR ROOF CROSS
 VENTILATION AS REQUIRED BY SEC. R806 OF 2010
 FBC-RESIDENTIAL.
  
 D) SPECIFY SIZE OF EXISTING FOOTING WHERE NEW CONCRETE
 BLOCK WALL IS GOING TO BE ERECTED. SEC. R401.2 OF 2010
 FBC-RESIDENTIAL.
  
 E) PROVIDE COMPLETE SPECIFICATIONS AND DETAILS FOR THE
 UNDER-FLOOR SPACE SHOWN. SPECIFY VENTILATION AND ACCESS
 AS REQUIRED BY SEC. R408 OF 2010 FBC-RESIDENTIAL.
  
 10 - DETAIL 1 ON SHEET A-4: NEED TO SPECIFY RING SHANK
 NAILS FOR ROOF SHEATHING FASTENING AS REQUIRED BY SEC.
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 11- ENERGY CALCULATIONS SUBMITTED:
 A) ENGINEER WHO PREPARED THE CALCULATIONS TO PROVIDE
 SIGNED AND SEALED DOCUMENTS AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE.
  
 B) CALCULATIONS SUBMITTED SHOWING COMPLIANCE WITH TOTAL
 UA ALTERNATIVE SEC. 402.1.1.3 OF THE 2010 FBC-ENERGY
 CONSERVATION ARE INCORRECT. THE DOORS AND FLOOR U
 FBC-2010 FACTORS ARE INCORRECT. ALSO, MISSING THE
 WINDOWS U FACTOR.
 (NOTE: THE A/C WALL UNIT NEED TO COMPLY WITH THE
 EQUIPMENT EFFICIENCY OF SEC. 402.1.2.4).
  
 C) REVISE FORM 402-2010: (1)ANSWERS FOR ITEMS #1 AND #2
 ARE INCORRECT. (2)ANSWERS FOR ITEMS #6(A), #6(B) AND
 #10(A) ARE INCORRECT. SEE GENERAL INSTRUCTION NOTE #2
 ON FIRST PAGE OF FORM. (3)COMPLETE ITEM #12(B). (3)ITEM
 # 14. PROVIDE EQUIPMENT SIZING CALCULATIONS AS REQUIRED
 BY SEC. 401.2 AND SEC. 403.6.1.1 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 12- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW GETTING THE R- 0.32 VALUE ON THE CONCRETE SLAB AS
 SPECIFIED ON THE ENERGY CALCULATIONS SUBMITTED. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 13- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW GETTING THE R-9.6 ON MASONRY WALLS AS SPECIFIED ON
 THE ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 14- PROVIDE DOCUMENTATION SHOWING COMPLIANCE WITH THE
 ACTUAL U-FACTOR USED IN THE CALCULATIONS USED FOR THE
 ENERGY CALCULATIONS. SEC. 103.2.2 AND SEC. 303.1.3 OF
 2010 FBC-ENERGY CONSERVATION.
  
 15- PLANS SPECIFY "RELOCATED A/C UNIT". THE UNIT IS
 SHOWN ON THE SAME LOCATION ON THE EXISTING AND
 DEMOLITION FLOOR PLAN AND IN THE PROPOSED PLANS AND
 ELEVATIONS. CLARIFY?. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: A/C RELOCATION REQUIRES MECHANICAL PERMIT. .
  
 16- STRUCTURAL WINDSTORM CALCULATIONS SUBMITTED:
 A) CALCULATIONS NEED TO BE PROPERLY SIGNED AND SEALED
 (ORIGINALS) AS REQUIRED BY CHAPTER 471 FL. ST.
  
 B) OPEN SHED: REVISE TYPE OF ROOF SHEATHING FASTENERS.
 ACCORDING TO SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL
 NEED TO USE 8D RING SHANK NAILS. REVISE CALCULATIONS
 AND DRAWINGS ACCORDINGLY OR PROVIDE CALCULATIONS
 SHOWING THAT 10D NAILS ARE EQUIVALENT TO THE RING SHANK
 NAILS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 C) SIZE OF 2-PLY GIRDERS SHOWN ON THE CALCULATIONS
 DOESN'T MATCH SIZE SHOWN ON PLANS SUBMITTED. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712