| Date |
Text |
| 2015-04-09 15:48:15 | BUILDING PLAN REVIEW |
| | PERMIT: 14120686 |
| | ADD: 906 GRANT ST. |
| | CONT: T. B. D. /AYALA MANUEL |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 3RD REVIEW |
| | DATE: THURS. APRIL 09/2015 |
| | ACTION: DENIED |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE |
| | MATERIAL.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION OF WORK TO BE |
| | COMPLETED UNDER THIS PERMIT. |
| | |
| | THE ONLY DIFFERENCE IN THE COMMENTS WILL BE IN THE UNIT |
| | WILL AFFECT THE COMMENT 4A)(1-2) , THIS COMMENT DEALS |
| | WITH THE ASSEMBLY OCCUPANCY IN THE 49 UNIT APPRTMENT |
| | BUILDING. |
| | |
| | 1-2) COMPLIED. |
| | |
| | 3RD REQUEST. 3) 4/28/2015. COMPLIED, THE CONTRACTOR |
| | WILL PRODUCE A JOB SUMMARY OR HISTORY FOR THIS TYPE OF |
| | CONSTRUCTION. |
| | |
| | NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE REQUIRED. |
| | FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE PERMIT |
| | LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND BATCH |
| | STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO SETS OF |
| | PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR THE |
| | RESIDENT INSPECTOR, THE OTHER FOR THE MEP INSPECTORS. |
| | |
| | PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS. |
| | |
| | 4-6) COMPLIED. |
| | |
| | .1.2. |
| | |
| | 7) PAGE 49 SHEET 1A-0.40 ROOF ACCESS & ROOF PLAN: |
| | 7A-D) COMPLIED. |
| | |
| | 7E) DEFERRED SUBMITTAL, ROOF TOP INSULATION PROVIDE THE |
| | ROOFTOP PRODUCT APPROVAL FOR INSULATION, LAYOUT SHEET |
| | FOR SLOPE AND ANCHORS TO BE SUBMITTED TO THE DESIGNER |
| | OF RECORD, REVIEWED, AND SHOP DRAWING STAMP OF APPROVAL |
| | AND OR WITH NOTES BEFORE SUBMITTAL TO THE BUILDING |
| | DEPARTMENT. |
| | |
| | |
| | 7F) COMPLIED. |
| | |
| | 8) BUILDING PROVISO |
| | THE OWNER/ CLIENT WILL OPT TO GET A FIELD TEST FROM A |
| | NATIONALLY RECONIZED TESTING AGENCY BEFORE A |
| | CERTIFICATE OF OCCUPANCY WILL BE ISSUED. AT OWN RISK |
| | NOT SUPPLYING TESTED ASSEMBLIES BEFORE PERMIT ISSUANCE. |
| | SITE TESTING FOR AIR-BORNE SOUND SHALL CONFORM TO ASTM |
| | E 90, WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED). |
| | |
| | |
| | 9) BUILDING PROVISO: 4/24/2015 REG ARCHITECTS ELECTS TO |
| | COMPLY WITH FIELD TESTING TO COMPLY WITH ASTM E-90. THE |
| | SUBMITTED INTERTEK REPORT # 3053682-001A IS FOR SOUND |
| | SEAL / CERAZORB 5 MM TESTED TO ASTM E 492 WITH RESULTS |
| | OF IIC OF 50. NOTE TO DATE THERE HAS BEEN NO TESTING |
| | SUBMITTED FOR ) FBC-B 2010 1207.2 1207.2 AIR-BORNE |
| | SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | |
| | 10 BUILDING PROVISO: PRODUCT APPROVALS WILL BE |
| | SUBMITTED AFTER PERMIT ISSUANCE AS A DEFERRED |
| | SUBMITTAL. 107.3.4.2 DEFERRED SUBMITTALS. FOR THE |
| | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE |
| | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT |
| | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE |
| | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A |
| | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL |
| | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE |
| | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE |
| | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION |
| | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| | COMPONENTS & CLADDING |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |