| 2015-02-03 11:56:52 | BUILDING PLAN REVIEW |
| | PERMIT: 14120661 |
| | ADD: 2601 OKEECHOBEE BLVD |
| | CONT: MASON DEVELOPMENT |
| | TEL: (561)623-8801 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: TUES. FEB. 03 /2015 |
| | ACTION: DENIED |
| | |
| | 1) COMPLIED. SHEET A0.01 CODE SUMMARY: |
| | |
| | |
| | 2) COMPLIED. ENERGY FORMS. |
| | |
| | 3) SEMI-COMPLIED/ PROVISO. 2010 FBC-B 1803.5.2 |
| | QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, STRENGTH |
| | OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR WHERE A |
| | LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS |
| | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE |
| | PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION |
| | BE CONDUCTED. |
| | |
| | 1803.6 REPORTING. WHERE GEOTECHNICAL INVESTIGATIONS ARE |
| | REQUIRED, A WRITTEN REPORT OF THE INVESTIGATIONS SHALL |
| | BE SUBMITTED TO THE BUILDING OFFICIAL BY THE OWNER OR |
| | AUTHORIZED AGENT AT THE TIME OF PERMIT APPLICATION. |
| | THIS GEOTECHNICAL REPORT SHALL INCLUDE, BUT NEED NOT BE |
| | LIMITED TO, THE FOLLOWING INFORMATION: |
| | 3.1. A PLOT SHOWING THE LOCATION OF THE SOIL |
| | INVESTIGATIONS. |
| | 3.2. A COMPLETE RECORD OF THE SOIL BORING AND |
| | PENETRATION TEST LOGS AND SOIL SAMPLES. |
| | 3.3. A RECORD OF THE SOIL PROFILE. |
| | 3.4. ELEVATION OF THE WATER TABLE, IF ENCOUNTERED. |
| | 3.5. RECOMMENDATIONS FOR FOUNDATION TYPE AND DESIGN |
| | CRITERIA, INCLUDING BUT NOT LIMITED TO: BEARING |
| | CAPACITY OF NATURAL OR COMPACTED SOIL; |
| | PROVISIONS TO MITIGATE THE EFFECTS OF EXPANSIVE SOILS; |
| | MITIGATION OF THE EFFECTS OF LIQUEFACTION, DIFFERENTIAL |
| | SETTLEMENT AND VARYING SOIL |
| | STRENGTH; AND THE EFFECTS OF ADJACENT LOADS. |
| | 3.6. EXPECTED TOTAL AND DIFFERENTIAL SETTLEMENT. |
| | |
| | NOTE: THE NEW SHEET S-2 THE NEW SOILS NOTES IT APPEARS |
| | THE ENGINEEER OF RECORD IS GOING TO BE THE SOILS |
| | ENGINEER AS WELL. IT APPEARS THE ENGINEER IS ASKING |
| | THIS CODE REQUIREMENT TO BE A DEFERRED SUBMITTAL, THE |
| | ABOVE REPORTING REQUIREMENTS WILL NEED TO BE INCLUDED |
| | IN THE SIGNED & SEALED DOCUMENTATION. |
| | |
| | 4) THIS BUILDING IS INDICATED AS HAVING 55,000 SQ. FT |
| | OF COMMERCIAL SPACE TO BE REMODELED, A LEVEL III |
| | ALTERATION. THIS BUILDING WILL QUALIFY FOR A ONSITE |
| | RESIDENT INSPECTOR. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 110.3.9 OTHER |
| | INSPECTIONS SERVICES. |
| | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY |
| | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: |
| | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE |
| | INCH |
| | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE |
| | FOOT |
| | |
| | NOTE; RESIDNET INSPECTOR PACKAGE AND FORMS WERE SENT |
| | TO, E-MAIL : [email protected] 12/20/2014 |
| | |
| | 4A) COMPLIED. SUCH INSPECTORS SHALL BE ADEQUATELY |
| | PRESENT AT TIMES WORK IS UNDERWAY ON THE STRUCTURAL |
| | ELEMENTS OF THE BUILDING. SUCH INSPECTORS SHALL BE A |
| | REGISTERED ARCHITECT, OR ENGINEER, OR A PERSON LICENSED |
| | UNDER CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH |
| | INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS |
| | INCLUDING THE DAILY INSPECTIONS TO THE BUILDING |
| | OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF |
| | THE RESIDENT INSPECTOR. |
| | |
| | 4B) NOTE ONLY NO ACTION REQUIRED. 2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 110.4 INSPECTION AGENCIES. THE BUILDING |
| | OFFICIAL IS AUTHORIZED TO ACCEPT REPORTS OF APPROVED |
| | INSPECTION AGENCIES, PROVIDED SUCH AGENCIES SATISFY THE |
| | REQUIREMENTS AS TO QUALIFICATIONS AND RELIABILITY. THE |
| | RESIDENT INSPECTOR AND ALL INTERESTED PARTIESSHALL FILE |
| | OUT AND BE NOTIRIZED, THE RESIDENT INSPECTOR FORMS AND |
| | RETURN TO THE CITY BEFORE PERMIT ISSUANCE, |
| | |
| | 4C)NOTE ONLY NO ACTION REQUIRED. 2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 110.5 INSPECTION REQUESTS. IT SHALL BE |
| | THE DUTY OF THE HOLDER OF THE BUILDING PERMIT OR THEIR |
| | DULY AUTHORIZED AGENT TO NOTIFY THE BUILDING OFFICIAL |
| | WHEN WORK IS READY FOR INSPECTION. IT SHALL BE THE DUTY |
| | OF THE PERMIT HOLDER TO PROVIDE ACCESS TO AND MEANS FOR |
| | INSPECTIONS OF SUCH WORK THAT ARE REQUIRED BY THIS |
| | CODE. |
| | |
| | 4D) 2ND REQUEST. PLEASE NOTE (3) SETS OF PLANS AND |
| | PRODUCT APPROVALS WILL BE REQUIRED, A 3RD SET FOR THE |
| | RESIDENT INSPECTOR. |
| | |
| | 4E) NEW NOTE: THE RESIDENT INSPECTOR FORMS SUBMITTED |
| | WERE FILLED OUT BY THE ENGINEER/ SPECIAL INSPECTOR, BUT |
| | THE PORTION TO BE FILLED OUT BY THE CONTRACTOR IS BLANK |
| | AND NOT NOTIRIZED. |
| | |
| | 5) MISSING WERE THE PRODUCT APPROVALS REQUIRED BY THE: |
| | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| | COMPONENTS & CLADDING, |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES NOTE CIRCLE |
| | SUB-SYSTEMS AND THE ASSOCIATED PRESSURES, SEE DESIGN |
| | LIMITATIONS. |
| | NOTE: THIS CAN BE A DEFERRED SUBMITTAL UNDER THE |
| | ROOFING PERMIT, TO DO THIS THERE WOULD BE A MINIMUM |
| | PLAN REVIEW CHARGE. |
| | |
| | 6) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 7-8) COMPLIED. |
| | |
| | 9A) COMPLIED.PLEASE SHOW COMPLIANCE WITH 2010 FBC-B |
| | 1509.6 1509.6 EQUIPMENT AND APPLIANCES ON ROOFS OR |
| | ELEVATED STRUCTURES. |
| | WHERE EQUIPMENT AND APPLIANCES REQUIRING ACCESS ARE |
| | INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT A HEIGHT |
| | EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE |
| | PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE |
| | EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO |
| | THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. |
| | |
| | 9B) NEW COMMENT: DEALS WITH THE LOCATION OF THE BILCO |
| | HATCH AND ROOF TOP A/C UNIT #1. SEE SHEETS A2.02 AND |
| | A3.04. SHEET A2.02 SHOWS BOTH THE BILCO HATCH AND RTU # |
| | 1 WITHIN 10'-0" OF THE PARAPET. SHEET A2.02 DOES NOT |
| | PROVIDE A CUT SECTION THROUGH THE BUILDING PROVIDING |
| | THE ROOF ELEVATION AND FINISH PARAPET HEIGHT. PLEASE |
| | SEE 2010 FBC-B SECTIONS: |
| | |
| | 1013.5 MECHANICAL EQUIPMENT. |
| | GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, |
| | FANS, ROOF HATCH OPENINGS OR OTHER COMPONENTS THAT |
| | REQUIRE SERVICE ARE LOCATED WITHIN 10 FEET (3048 MM) OF |
| | A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH |
| | EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 |
| | MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE GUARD |
| | SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A |
| | SPHERE 21 INCHES (533 MM) IN DIAMETER. THE GUARD SHALL |
| | EXTEND NOT LESS THAN 30 INCHES (762 MM) BEYOND EACH END |
| | OF SUCH APPLIANCE, EQUIPMENT, FAN OR COMPONENT. |
| | |
| | 1013.6 ROOF ACCESS. |
| | GUARDS SHALL BE PROVIDED WHERE THE ROOF HATCH OPENING |
| | IS LOCATED WITHIN 10 FEET (3048 MM) OF A ROOF EDGE OR |
| | OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN |
| | SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE |
| | FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL BE |
| | CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21 |
| | INCHES (533 MM) IN DIAMETER. |
| | |
| | |
| | 10-13) COMPLIED. |
| | |
| | 14) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |