2014-12-18 10:39:32RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND
 CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC.
 109.3 CITY AMENDMENTS TO FBC. VALUATION WAS UPDATED TO
 $8,700. THE PERMIT FEE BALANCE IS $260.70.
  
 2- FLAT ROOF:
 A) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE FLAT ROOF SYSTEM TO BE INSTALLED.
  
 B) CLEARLY IDENTIFY WHICH APPROVED FLAT ROOF SYSTEM AND
 BASE SHEET FASTENING OPTION FROM PRODUCT APPROVAL
 PROVIDED IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 C) IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES REQUIRED BY SEC. R301.1, THEN PROVIDE SIGNED
 AND SEALED NAIL ENHANCING CALCULATIONS (2 COPIES WITH
 ORIGINAL SEAL AND SIGNATURE). CALCULATIONS ARE USUALLY
 REFERRED AS RAS 117 CALCULATIONS.
  
 3- SPECIFY SHINGLES ROOF PITCH TO VERIFY COMPLIANCE
 WITH SEC. R905.2.2 OF 2010 FBC-RESIDENTIAL.
  
 4- NOTICE OF COMMENCEMENT IS REQUIRED BY SEC,. 713 OF
 FLORIDA STATUTE.
  
 ***NOTE: PERMIT APPLICATION NEEDS OWNER'S NOTARIZED
 SIGNATURE.
  