| 2014-12-16 15:26:04 | PROVISIONAL APPROVAL: |
| | |
| | BASED UPON PHOTOGRAPHIC EVIDENCE SUBMITTED AND FIELD |
| | INSPECTOR INPUT THIS PERMIT IS ISSUED SO THAT A FLORIDA |
| | REGISTERED ENGINEER MAY MAKE THE DETERMINATION AS TO |
| | THE LEVEL OF STRUCTURAL DAMAGE AND SPECIFY REPAIRS |
| | PURSUANT TO THE SECTION BELOW: |
| | |
| | FLORIDA BUILDING CODE EXISTING |
| | SECTION 506 |
| | STRUCTURAL |
| | |
| | 506.1 GENERAL. |
| | STRUCTURAL REPAIRS SHALL BE IN COMPLIANCE WITH THIS |
| | SECTION AND SECTION 501.2. REGARDLESS OF THE EXTENT OF |
| | STRUCTURAL OR NONSTRUCTURAL DAMAGE, DANGEROUS |
| | CONDITIONS SHALL BE ELIMINATED. REGARDLESS OF THE SCOPE |
| | OF REPAIR, NEW STRUCTURAL MEMBERS AND CONNECTIONS USED |
| | FOR REPAIR OR REHABILITATION SHALL COMPLY WITH THE |
| | DETAILING PROVISIONS OF THE FLORIDA BUILDING CODE, |
| | BUILDING FOR NEW BUILDINGS OF SIMILAR STRUCTURE, |
| | PURPOSE AND LOCATION. |
| | |
| | 506.1.1 |
| | NONSTRUCTURAL REPAIRS EXCLUSIVE OF FIXTURES AND |
| | FURNITURE, THE COST OF WHICH DOES NOT EXCEED 25 PERCENT |
| | OF THE REPLACEMENT VALUE OF THE EXISTING BUILDING OR |
| | STRUCTURE, WITH THE APPROVAL OF THE BUILDING OFFICIAL, |
| | MAY BE MADE OF THE SAME MATERIAL OF WHICH THE BUILDING |
| | OR STRUCTURE IS CONSTRUCTED. |
| | |
| | EXCEPTION: HISTORIC BUILDINGS SHALL COMPLY WITH SECTION |
| | 502.4. |
| | |
| | 506.2 REPAIRS TO DAMAGED BUILDINGS. |
| | REPAIRS TO DAMAGED BUILDINGS SHALL COMPLY WITH THIS |
| | SECTION AND SECTION 611, REROOFING. |
| | |
| | 506.2.1 REPAIRS FOR LESS THAN SUBSTANTIAL STRUCTURAL |
| | DAMAGE. |
| | FOR DAMAGE LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE, THE |
| | DAMAGED ELEMENTS SHALL BE PERMITTED TO BE RESTORED TO |
| | THEIR PREDAMAGE CONDITION. |
| | |
| | 506.2.2 REPAIRS FOR SUBSTANTIAL STRUCTURAL DAMAGE TO |
| | ELEMENTS OF THE LATERAL-FORCE-RESISTING SYSTEM. |
| | A BUILDING THAT HAS SUSTAINED SUBSTANTIAL STRUCTURAL |
| | DAMAGE TO THE ELEMENTS OF ITS LATERAL FORCE-RESISTING |
| | SYSTEM SHALL BE EVALUATED IN ACCORDANCE WITH SECTION |
| | 506.2.2.1, AND EITHER REPAIRED IN ACCORDANCE WITH |
| | SECTION 506.2.2.2 OR REPAIRED AND REHABILITATED IN |
| | ACCORDANCE WITH SECTION 506.2.2.3 DEPENDING ON THE |
| | RESULTS OF THE EVALUATION. |
| | |
| | 506.2.2.1 EVALUATION. |
| | THE BUILDING SHALL BE EVALUATED BY A REGISTERED DESIGN |
| | PROFESSIONAL, AND THE EVALUATION FINDINGS SHALL BE |
| | SUBMITTED TO THE CODE OFFICIAL. THE EVALUATION SHALL |
| | ESTABLISH WHETHER THE DAMAGED BUILDING, IF REPAIRED TO |
| | ITS PREDAMAGED STATE, WOULD COMPLY WITH THE PROVISIONS |
| | OF THE CODES THAT WERE IN EFFECT WHEN THE BUILDING WAS |
| | PERMITTED. |
| | |
| | 506.2.2.2 EXTENT OF REPAIR FOR COMPLIANT BUILDINGS. |
| | IF THE EVALUATION ESTABLISHES THAT THE BUILDING IN ITS |
| | PREDAMAGE CONDITION COMPLIES WITH THE PROVISIONS OF |
| | SECTION 506.2.2.1, THEN THE DAMAGED ELEMENTS SHALL BE |
| | PERMITTED TO BE RESTORED TO THEIR PREDAMAGE CONDITION. |
| | |
| | 506.2.2.3 EXTENT OF REPAIR FOR NONCOMPLIANT BUILDINGS. |
| | IF THE EVALUATION DOES NOT ESTABLISH THAT THE BUILDING |
| | IN ITS PREDAMAGE CONDITION COMPLIES WITH THE PROVISIONS |
| | OF SECTION 506.2.2.1, THEN THE BUILDING SHALL BE |
| | REHABILITATED TO COMPLY WITH THE PROVISIONS OF THIS |
| | SECTION. THE WIND LOAD FOR THE REPAIR AND |
| | REHABILITATION SHALL BE THOSE REQUIRED BY THE BUILDING |
| | CODE IN EFFECT AT THE TIME OF ORIGINAL CONSTRUCTION, |
| | UNLESS THE DAMAGE WAS CAUSED BY WIND, IN WHICH CASE THE |
| | WIND LOADS SHALL BE IN ACCORDANCE WITH THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |