| Date |
Text |
| 2015-02-28 15:49:24 | ****CORRECTIONS**** |
| | ELEVATION CERTIFICATE DATED 12/3/14 PREPARED BY ROBERT |
| | J CAJAL, WALLACE SURVEYING CORP |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | ALL COMMENTS FROM PREVIOUS REVIEW DATED 12/11/2014 |
| | STILL APPLY WITH THE EXCEPTION OF ITEM C2A WHICH HAS |
| | BEEN REVISED AS NO OTHER INFORMATION HAS BEEN CORRECTED |
| | OR REVISED. IT IS NOT CLEAR WHY A REVIEW WAS DONE ON AN |
| | ELEVATION CERTIFICATE DATED 12/9/14, BUT THE LATEST |
| | ELEVATION CERTIFICATE SUBMITTED IS DATED 12/3/14. |
| | PLEASE HAVE SURVEYOR EXPLAIN THE DISCREPANCY. |
| | |
| | FOR YOUR CONVENIENCE, COMMENTS ARE AS FOLLOWS: |
| | |
| | 1. A1, A2, A3, IT IS MY UNDERSTANDING THAT THIS PARCEL |
| | IS UNDERGOING A REPLAT. REVISE THE INFORMATION IN THESE |
| | FIELDS IF APPLICABLE. |
| | |
| | 2ND REVIEW, PLEASE ADVISE. INFORMATION ON ELEVATION |
| | CERTIFICATE HAS NOT BEEN REVIVSED. |
| | |
| | 2. A5, LATITUDE/LONGITUDE DOES NOT APPEAR TO BE |
| | CORRECT. THIS IS TO BE ACCURATE WITHIN 66' OF THE |
| | CENTER OF THE FRONT OF THE BUILDING. THE LOCATION |
| | APPEARS TO BE NEAR THE PORTION OF THE EXISTING |
| | RESIDENCE WHICH WAS TO BE DEMOLISHED. |
| | |
| | 2ND REVIEW, INFORMATION HAS NOT BEEN REVISED AND NO |
| | EXPLANATION OR DISPUTE PROVIDED. |
| | |
| | 3. PLANS (AND NFIP, CITY OF WEST PALM BEACH MUNICIPAL |
| | CODE) REQUIRE THAT THE FINISHED FLOOR BE AT 7.5'. 7.4' |
| | IS SHOWN ON THE ELEVATION CERTIFICATE IN ITEM C2D (ITEM |
| | S C2A HAS BEEN REVISED TO 7.5'). PLEASE ADDRESS. |
| | |
| | 4. B1, NFIP COMMUNITY NAME IS "CITY OF WEST PALM BEACH" |
| | (REMOVE "UNINCORPORATED"). |
| | |
| | 5. B6, FIRM INDEX DATE SHOULD BE 03/01/1979. |
| | |
| | 6. C2E, EQUIPMENT ELEVATION IS 8.3, BUT PHOTOGRAPHS DO |
| | NOT APPEAR TO SHOW THE MECHANICAL EQUIPEMENT NEARLY A |
| | FOOT HIGHER THAN THE GARAGE FLOOR. PLEASE CONFIRM THAT |
| | THIS ELEVATION IS CORRECT. |
| | |
| | 7. PAGE 2, BUILDING STREET ADDRESS, PLEASE REVISE IF |
| | ADDRESS OF STRUCTURE HAS CHANGED. |
| | |
| | 2. FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS TO BE |
| | DONE AFTER ALL FINISHED GRADING IS COMPLETE. PROVIDE |
| | PICTURES WHICH DEPICT THE BUILDING AND THE ADJACENT |
| | GRADE IN A MORE COMPLETE STATE. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |