Date Text
2014-12-12 09:08:23BUILDING PLAN REVIEW
 PERMIT: 14120355
 ADD: 1703 PALM BEACH LAKES BLVD # H-03
 CONT: DUFFY SOUTHEAST
 TEL: (???)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. DEC. 12/12/14
 ACTION: DENIED
  
 1A) NOTE: PALM BEACH OUTLET MALL: BEFORE PLAAN
 SUBMITTAL TO THE BUILDING DEPARTMENT, THE PLANS ARE
 SUPPOSE TO HAVE THE STAMPED LANDLORD APPROVAL BY NEW
 ENGLAND DEVELOPMNT PALM BEACH OUTLETS SKE GROUP TENANT
 COORDINATOR.
  
 1B) THE OWNERS NOTIRIZED SIGNATURE IS MISSING ON THE
 PERMIT APPLICATION.
  
 2) PLEASE REVIEW THE OCCUPANT LOAD FOUND ON THE LIFE
 SAFETY SHEET A.02 INDICATES INDICATES 25 OCCUPANTS
 SERVED BY THE FRONT ENTRY. THE COVER SHEET SHOWS 1057
 SQ. FT. MERCANTILE/ 30= 36 OCCUPANTS
 295 SQ. FT. BOH / 300= 1 OCCUPANT
 TOTAL OCCUPANT LOAD 37 OCCUPANTS SEE 2010 FBC-B TABLE
 1004.1.1. PLEASE CORRECT.
  
 3) SHEET A 4.1:
 3A) DISCREPANCY IN PLANS DETAILS 2 & 3 BOTH REFERANCE
 SEE DETAIL1/ A2.3, THIS SHEET IS NOT FOUND IN THE SET
 OF PLANS NOR IN THE SHEET INDEX. 107.2.1.3 ADDTIONAL
 INFORMATION REQUIRED.
  
 3B) DISCREPANCY IN PLANS DETAILS 1 VERSES 3, DETAIL # 3
 IS A FOOT SHORTER AT 6'-3" THAN DETAIL # 1 DOES NOT
 COMPLY WITH 2010 FL ACCESS. CODE 604.3.2.
  
 3C) SECTION ELEVATION DETAILS 2 & 3 INDICATE THE GRAB
 RAILS TO BE SET AT THE MAXIMUM HEIGTH OF 36 INCHES,
 NOTE AS DEPICTED THEY ARE SHOWN AT 36 INCHES TO THE
 CENTER LINE OF THE GRAB BAR. 2010 FL ACCESS. CODE 609.4
 THE HEIGTH MEASUREMENT IS TAKEN AT THE TOP OF THE GRAB
 BAR, THE TOP OF THE GRASPING SURFACE.
  
 3D) THE WATER CLOSET DOES NOT SHOW THE FLUSH CONTROL,
 IF A HAND FLUSH CONTROL IT MUST BE ON THE OPEN SIDE
 (TRANSFER SIDE), 2010 FBC-ACCESSIBILITY 604.6.
  
 4) SHEETS A6.1 & A7.1 THE CASH WRAP PLEASE SHOW
 COMPLIANCE WITH 2010 FL ACCESS. CODE 904.4 SALES AND
 SERVICE COUNTERS.
 SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH
 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE
 COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR
 SERVICE COUNTER TOP.
  