| Date |
Text |
| 2014-12-12 09:08:23 | BUILDING PLAN REVIEW |
| | PERMIT: 14120355 |
| | ADD: 1703 PALM BEACH LAKES BLVD # H-03 |
| | CONT: DUFFY SOUTHEAST |
| | TEL: (???)373-3902 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. DEC. 12/12/14 |
| | ACTION: DENIED |
| | |
| | 1A) NOTE: PALM BEACH OUTLET MALL: BEFORE PLAAN |
| | SUBMITTAL TO THE BUILDING DEPARTMENT, THE PLANS ARE |
| | SUPPOSE TO HAVE THE STAMPED LANDLORD APPROVAL BY NEW |
| | ENGLAND DEVELOPMNT PALM BEACH OUTLETS SKE GROUP TENANT |
| | COORDINATOR. |
| | |
| | 1B) THE OWNERS NOTIRIZED SIGNATURE IS MISSING ON THE |
| | PERMIT APPLICATION. |
| | |
| | 2) PLEASE REVIEW THE OCCUPANT LOAD FOUND ON THE LIFE |
| | SAFETY SHEET A.02 INDICATES INDICATES 25 OCCUPANTS |
| | SERVED BY THE FRONT ENTRY. THE COVER SHEET SHOWS 1057 |
| | SQ. FT. MERCANTILE/ 30= 36 OCCUPANTS |
| | 295 SQ. FT. BOH / 300= 1 OCCUPANT |
| | TOTAL OCCUPANT LOAD 37 OCCUPANTS SEE 2010 FBC-B TABLE |
| | 1004.1.1. PLEASE CORRECT. |
| | |
| | 3) SHEET A 4.1: |
| | 3A) DISCREPANCY IN PLANS DETAILS 2 & 3 BOTH REFERANCE |
| | SEE DETAIL1/ A2.3, THIS SHEET IS NOT FOUND IN THE SET |
| | OF PLANS NOR IN THE SHEET INDEX. 107.2.1.3 ADDTIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 3B) DISCREPANCY IN PLANS DETAILS 1 VERSES 3, DETAIL # 3 |
| | IS A FOOT SHORTER AT 6'-3" THAN DETAIL # 1 DOES NOT |
| | COMPLY WITH 2010 FL ACCESS. CODE 604.3.2. |
| | |
| | 3C) SECTION ELEVATION DETAILS 2 & 3 INDICATE THE GRAB |
| | RAILS TO BE SET AT THE MAXIMUM HEIGTH OF 36 INCHES, |
| | NOTE AS DEPICTED THEY ARE SHOWN AT 36 INCHES TO THE |
| | CENTER LINE OF THE GRAB BAR. 2010 FL ACCESS. CODE 609.4 |
| | THE HEIGTH MEASUREMENT IS TAKEN AT THE TOP OF THE GRAB |
| | BAR, THE TOP OF THE GRASPING SURFACE. |
| | |
| | 3D) THE WATER CLOSET DOES NOT SHOW THE FLUSH CONTROL, |
| | IF A HAND FLUSH CONTROL IT MUST BE ON THE OPEN SIDE |
| | (TRANSFER SIDE), 2010 FBC-ACCESSIBILITY 604.6. |
| | |
| | 4) SHEETS A6.1 & A7.1 THE CASH WRAP PLEASE SHOW |
| | COMPLIANCE WITH 2010 FL ACCESS. CODE 904.4 SALES AND |
| | SERVICE COUNTERS. |
| | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| | SERVICE COUNTER TOP. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |