| Notes |
| Date |
Text |
| 2014-12-29 13:05:16 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1-DETACHED BEDROOM. AFTER PLANS ARE REVISED BRING THEM | | | TO PALM BEACH COUNTY (2300 N. JOG RD.) TO VERIFY IF | | | IMPACT FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS | | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY | | | THE COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. | | | | | | 2- DETACHED BEDROOM #4 WINDOW DOESN'T COMPLY WITH THE | | | EGRESS MIN. HEIGHT REQUIREMENTS OF SEC. R310.1.2 OF | | | 2010 FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 3-- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | 4- REVISE THE COMPONENTS AND CLADDING DESIGN PRESSURES | | | SHOWN ON THE DESIGN PARAMETERS ON SHEET 2 OF 3. THOSE | | | PRESSURES DON'T MEET THE DESIGN PRESSURES FOR EXPOSURE | | | "C" FOR WINDOWS/DOORS LOCATED ON THE END ZONES. REVISE | | | AS REQUIRED. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. | | | | | | ***PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|