2014-11-30 16:07:221ST REVIEW: FBC 2010
  
 YOU HAVE PROVIDED DESIGN PRESSURES FOR EXPOSURE C.
 PLEASE PROVIDE DESIGN PRESSURES BASED ON EXPOSURE D:
  
 1609.4.3 EXPOSURE CATEGORIES.
 AN EXPOSURE CATEGORY SHALL BE DETERMINED IN ACCORDANCE
 WITH THE FOLLOWING:
  
 EXPOSURE B. FOR BUILDINGS WITH A MEAN ROOF HEIGHT OF
 LESS THAN OR EQUAL TO 30 FEET, EXPOSURE B SHALL APPLY
 WHERE THE GROUND SURFACE ROUGHNESS AS DEFINED BY
 SURFACE ROUGHNESS B PREVAILS IN THE UPWIND DIRECTION
 FOR A DISTANCE OF AT LEAST 1,500 FT (457 M). FOR
 BUILDINGS WITH A MEAN ROOF HEIGHT GREATER THAN 30 FEET,
 EXPOSURE B SHALL APPLY WHERE SURFACE ROUGHNESS B
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 2,600 FEET (792 M) OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER.
  
 EXPOSURE C. EXPOSURE C SHALL APPLY FOR ALL CASES WHERE
 EXPOSURES B OR D DO NOT APPLY.
  
 EXPOSURE D. EXPOSURE D SHALL APPLY WHERE THE GROUND
 SURFACE ROUGHNESS, AS DEFINED BY SURFACE ROUGHNESS D,
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 5,000 FEET (1524 M) OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER. EXPOSURE D SHALL EXTEND
 INLAND FROM THE SHORELINE FOR A DISTANCE OF 600 FEET
 (183 M) OR 20 TIMES THE HEIGHT OF THE BUILDING,
 WHICHEVER IS GREATER FROM AN EXPOSURE D CONDITION AS
 DEFINED IN THE PREVIOUS SENTENCE.
  
 ADDITIONALLY, PLEASE INDICATE THE SELECTED IS IT ORIEL
 TYPE, UNEQUAL LITES, OR EQUAL LITES . PLEASE INDICATE
 BY MARKING THE PRODUCT APPROVAL OR OTHERWISE. ALSO,
 INDICATE ON THE PRODUCT APPROVAL, OR OTHERWISE, HOW YOU
 FOLLOWED THE INSTRUCTIONS ON SHEET 1 OF 9 FOR THE
 MULLION, AND SHOW THE SELECTED ANCHOR OPTION YOU ARE
 CHOOSING.
  
 THE APPLICATION STATES A VALUE OF $2,800.00 HOWEVER,
 THERE IS A CONTRACT ATTACHED INDICATING A VALUE OF
 $4,200.00 THE VALUE WILL BE ADJUSTED TO $4,200.00.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  