| 2015-11-25 16:08:46 | RESIDENTIAL (R3) ADDITION, THIRD BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: 2010 FBC. |
| | |
| | NOTE: |
| | NEW SET OF DRAWINGS SUBMITTED DONE BY ANOTHER ENGINEER |
| | OF RECORD. |
| | |
| | 1- SHEET S-000: CODE REFERENCED ON THE WIND LOADING |
| | (MWFRS) DOESN'T MATCH CODE REFERENCED ON THE WIND |
| | LOADING (C&C). REVISE AS REQUIRED TO MATCH. NOTE: THE |
| | CODE UNDER WHICH THE REVIEWS ARE DONE FOR THIS PROJECT |
| | IS THE 2010 FBC. |
| | |
| | 2- PROVIDE DETAILS AND SPECIFICATIONS SHOWING |
| | COMPLIANCE WITH THE NEW ROOF CROSS VENTILATION AS |
| | REQUIRED BY SEC. R806 OF 2010 FBC-RESIDENTIAL. |
| | INFORMATION SHOWN ON THE TYPICAL WALL SECTION ON SHEET |
| | S-300 IS NOT CLEAR. IT'S NOT CLEAR IF ENGINEER OF |
| | RECORD IS DESIGNING AN UNVENTED ATTIC OR A VENTED |
| | ATTIC. NOT CLEAR WHY SPECIFYING RIGID BOARD R-5 |
| | INSULATION ABOVE ROOF SHEATHING AND R-30 BATT |
| | INSULATION BETWEEN ROOF JOISTS. AND, THERE ARE |
| | SPECIFICATIONS FOR "PROTECTED ROOF VENTS FOR ROOF CROSS |
| | VENTILATION". ON THE OTHER HAND, THE WAY THE CROSS |
| | VENTILATION IS SPECIFIED DOESN'T PROVIDE CROSS |
| | VENTILATION. REVISE AS REQUIRED. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 3- FOUNDATION SCHEDULE ON SHEET S-301 IS MISSING ONE |
| | DIMENSION FOR FOOTING WF-1. PROVIDE COMPLETE |
| | INFORMATION. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 4- ROOF FRAMING PLAN ON SHEET S-101: SPECIFY SPACING OF |
| | 2X12 JOISTS. SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 5- BASED ON THE EXTERIOR ELEVATIONS SHOWN ON SHEET |
| | S-200, THERE DOESN'T SEEM TO BE 24" CLEAR CRAWL SPACE |
| | AS SHOWN ON TYPICAL WALL SECTION ON SHEET S-300. |
| | CLARIFY AS REQUIRED. CLEARLY PROVIDE THE CRAWL SPACE |
| | CLEARANCE THAT MATCHES EXTERIOR ELEVATIONS. THIS IS |
| | IMPORTANT BECAUSE THE FLOOR JOIST NEED TO COMPLY WITH |
| | THE WOOD DECAY PROTECTION AS REQUIRED BY SEC. R317.1 OF |
| | 2010 FBC-RESIDENTIAL IF THE CLEARANCE IS LESS THAN 18" |
| | . ON THE OTHER HAND, THE EXTERIOR WOOD DECK MAY |
| | REQUIRED GUARDRAILS. SEE SEC. R312 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 6- PROVIDE COMPLETE SPECIFICATIONS FOR TYPE OF CRAWL |
| | SPACE ACCESS DOOR. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | F.A.C. 61G20-3.002(33) FOR: |
| | A) CRAWL SPACE ACCESS DOOR AS SHOWN ON PLANS. |
| | |
| | 8- ENGINEER OF RECORD TO APPROVE IN WRITING (NOT |
| | SIGNING AND SEALING) ABOVE PRODUCT APPROVAL. SEC. |
| | 107.3.4.1 OF CITY AMENDMENTS. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE REMOVE ANY REVISED SHEET. DON'T STAPPLE OLD |
| | COPY TO PLANS. SUBMITT OLD COPIES FOR REFERENCE. |
| | |