2014-11-27 06:25:331) SHT.A-1 - EXISTING NOTES - THE PLANS REFER TO
 EXISTING TOILET ROOMS AND DRINKING FOUNTAIN LOCATED IN
 COMMON AREA CORRIDOR AS SHOWN ON FLOOR PLAN 1/A-1.
 NOTHING IS SHOWN. CLARIFY.WPB AMEND. TO 2010 FBC SEC.
 107.2.1.
 2) SUBMIT THE OCCUPANT LOAD FOR BOTH AREAS IN THE
 WAREHOUSE. 2010 FBC SEC. 1004.1.1.
 3) NOTE ON SHT. A-2 REFERS TO CODE SEC. FBC 11-4.1.6
 (2). THERE IS NO SUCH CODE SECTION. CLARIFY.
 4) LIST ALL THE DIFFERENT OCCUPANCIES ON THE PLANS FOR
 THE WAREHOUSE AREA. WPB AMEND. TO 2010 FBC SEC.
 107.2.1.
 5) INDICATE ON THE PLANS THE TYPE OF OPERATIONS TO BE
 DONE IN THE WORK ROOM AREA IN THE WAREHOUSE. WPB AMEND.
 TO 2010 FBC SEC. 107.2.1.
 6) SHT. "T" INDICATES THE EXISTING WAREHOUSE BUILDING
 AS A GROUP "B" OCCUPANCY BUT SHT.A-2 SHOWS SUITE 100 AS
 RETAIL WHICH WOULD CONSTITUTE A CHANGE OF OCCUPANCY AND
 CCOMPLY WITH THE 2010 FLORIDA EXISTING BUILDING CODE
 CHAPTER 9.7) A DRINKING FOUNTAIN MAY BE REQUIRED IN THE
 WAREHOUSE SUITES DEPENDING UPON THE OCCUPANT LOAD PER
 TABLE 403.1.OF THE FPC.
 7) SHT.A-5 - THE HEIGHT OF THE GRAB BARS SHALL BE
 MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT TO THE
 CENTERLINE PER THE FL. ACCESS. CODE SEC. 609.4.
 8) SINCE THE SECOND FLOOR IS AN R-2 OCUUPANCY, ONE
 AUTOMATIC CLOTHES WASHER CONNECTION SHALL BE PROVIDED
 PER 20 UNITS PER TABLE 403.1 OF THE 2010 FL. PLBG. CODE
  