| Plan Review Notes For Permit 14110652 |
| Permit Number |
14110652 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-12-05 15:27:48 | 12/5/2014 | | | PROJECT: UNIVERSAL CHURCH SIGN | | | PERMIT#: 14110652 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION. | | | | | | 1) ELECTRIC SIGNS, SECTION SIGNS, AND OUTLINE LIGHTING | | | ? FIXED, MOBILE, OR PORTABLE ? SHALL BE LISTED AND | | | INSTALLED IN CONFORMANCE WITH THAT LISTING, UNLESS | | | OTHERWISE APPROVED BY SPECIAL PERMISSION. 600.3 | | | LISTING. | | | | | | 2) EACH SIGN AND BRANCH CIRCUIT SUPPLYING A SIGN SHALL | | | BE CONTROLLED BY AN EXTERNALLY OPERABLE SWITCH OR | | | CIRCUIT BREAKER THAT WILL OPEN ALL UNGROUNDED | | | CONDUCTORS WITHIN SIGHT OF THE SIGN THAT IT CONTROLS. | | | NEC 600.6(A)(1) | | | | | | 3) ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 505.1 | | | SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT | | | OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & | | | TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME | | | SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING | | | DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS. FBC-E | | | 505.2.4 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | | | | | | | |
|