| 2014-11-12 08:54:12 | BUILDING PLAN REVIEW |
| | PERMIT: 14110387 |
| | ADD: 3200 N. MILITARY TRAIL |
| | CONT: ADVANCED ROOFING, INC. |
| | TEL: (954)522-6868 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. NOV. 12/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) CHARITY WORK, VALUE SHOWN $6,000.00 DOLLORS VALUE OF |
| | WORK. CALCULATED VALUE OF $11,005.00. 108.3* BUILDING |
| | PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 2) ROOFING ENGINEERING FROM ATLANTIC & CARIBBEAN ROOF |
| | CONSULTING, DATA SHEET INDICATES NOA # 12-0828.03 PAGE |
| | 7. PAGE 8 SUBMITTED MAXIMUM DESIGN PRESSURE OF SHEET #8 |
| | IS -75 PSF WITH GENERAL LIMITATION #9. NO ENHANCED |
| | FASTENING ALLOWED. SUBMIT THE CORRECT SHEET # 7. |
| | |
| | 3A) NOA 13-0828.03 SHEET # 7 MAXIMUM DESIGN PRESSURE OF |
| | -105 PSF. THE PRODUCT APPROVAL PAGE #7 BASE INSULATION |
| | LAYER TYPE OF INSULATION AND INSULATION FASTENER (TABLE |
| | 3) IS NOT CIRCLED (IDENTIFIED). THE ENGINEERING LETTER |
| | STATES REFER TO RAS 117 FOR INSULATION ATTACHMENTS, |
| | PLEASE PROVIDE THE TYPE OF INSULATION TO BE INSTALLED |
| | FROM THE LIST IN THE PRODUCT APPROVAL PAGE # 7 AND THE |
| | TYPE OF FASTENER PER TABLE 3 AND THE DENSITY OF |
| | REQUIRED FASTENERS FOR ZONES 1, 2 & 3. |
| | |
| | 3B) IF THE PAGE 8 OF THE LISTED ABOVE NOA IS CORRECT |
| | THEN THE ENGINEERING LETTER IS WRONG AND WILL REQUIRE A |
| | NEW ENGINEERING LETTER. NOTE SHEET # 8 THE MAXIMUM |
| | DESIGN PRESSURE OF -75 PSF GENERAL LIMITATION #9. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |