| 2014-12-11 12:34:46 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- DRAWINGS NEED THE ORIGINAL SEAL AND SIGNATURE OF THE |
| | ENGINEER RESPONSIBLE FOR THE DESIGN AS REQUIRED BY |
| | CHAPTER 471 FLORIDA STATUTE. |
| | |
| | 2- SPECIFY THE SIZE OF THE NEW BEDROOM EGRESS WINDOW. |
| | PLANS SUBMITTED DON'T SPECIFY THE SIZE. SEC. R310 |
| | FBC-RESIDENTIAL. |
| | |
| | 3- PROVIDE COMPLETE SPECIFICATIONS FOR THE NEW MASONRY |
| | OPENING TO RECEIVE NEW EGRESS WINDOW. PROVIDE COMPLETE |
| | SPECIFICATIONS FOR THE COLUMNS AND REINFORCING. |
| | DRAWINGS SUBMITTED SHOW COLUMNS ON BOTH SIDES OF |
| | OPENING, BUT THERE ARE NO SPECIFICATIONS. SEC. R301 OF |
| | 2010 FBC-RESIDENTIAL. |
| | |
| | 4- REVISE CONNECTOR SCHEDULE. CLEARLY IDENTIFY WHICH |
| | SPECIFIC H10 SIMPSON STRUCTURAL CONNECTORS IS GOING TO |
| | BE USED. THERE ARE MANY TYPES OF H10 CONNECTORS ON THE |
| | SIMPSON CATALOG. AND, REVISE THE NAIL SIZE AND NUMBER |
| | OF NAILS FOR ALL CONNECTORS TO MATCH PRODUCT APPROVAL |
| | SPECS. SEC. R301 OF 2010 FBC-RESIDENTIAL. OTHERWISE, |
| | ENGINEERING ANALYSIS WILL BE REQUIRED FOR NAILING OTHER |
| | THAN THE SPECIFIED ON THE PRODUCT APPROVAL. |
| | |
| | 5- WALL SECTION SUBMITTED: |
| | A) ENGINEER OF RECORD TO PROVIDE DETAILS AND |
| | SPECIFICATIONS SHOWING COMPLIANCE WITH THE ROOF CROSS |
| | VENTILATION AS REQUIRED BY SEC. R806 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | B) ENGINEER OF RECORD TO PROVIDE COMPLETE |
| | SPECIFICATIONS FOR THE ROOF OUTLOOKERS. SPECIFY SIZE |
| | AND FASTENERS. SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| | |
| | C) REVISE STUCCO THICKNESS TO COMPLY WITH TABLE |
| | R702.1(1) OF 2010 FBC-RESIDENTIAL. NEED 7/8" MIN. |
| | |
| | D) NEED TO SHOW NOT LESS THAN 6" CLEARANCE FROM GRADE |
| | TO STUCCO AS REQUIRED BY SEC. R704 OF 2010 |
| | FBC-RESIDENTIAL. REVISE DRAWING AS REQUIRED. |
| | |
| | 6- ENERGY CALCULATIONS: |
| | A) ENGINEER WHO PREPARED THE CALCULATIONS TO PROVIDE |
| | NAME, LICENSE NUMBER AS REQUIRED BY CHAPTER 471 FLORIDA |
| | STATUTE. |
| | |
| | B) FORM NEEDS TO BE SIGNED AND DATED BY THE |
| | OWNER/AGENT. SEC. 103.2.3 OF 2010 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | C) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF |
| | FORM. THE CONTRACTOR IS NOT THE OWNER. REVISE AS |
| | REQUIRED. AND, COMPLETE THE PERMIT OFFICE AND |
| | JURISDICTION NUMBER. SEC. 103.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | D) REVISE THE ROOF MATERIAL SHOWN ON PAGE 2 OF 5. THERE |
| | ARE NOT SHINGLES ON THIS HOUSE. SEC. 103.2.2 OF 2010 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | E) REVISE THE DOOR INFORMATION SHOWN ON PAGE 3 OF 5. |
| | THERE ARE NOT WOOD DOORS. THERE ARE NOT 3 EXTERIOR |
| | DOORS EITHER. REVISE THE DOOR ORIENTATION. SEE PLANS |
| | AND PRODUCT APPROVALS AND REVISE AS REQUIRED. SEC. |
| | 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | F) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 5. |
| | REVISE THE ORIENTATION TO MATCH PLANS. REVISE THE |
| | OVERHANG DEPTH AND SEPARATION TO MATCH PLANS. SEC. |
| | 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | 7- PROVIDE MANUFACTURER SPECS FOR WINDOWS AND DOORS |
| | SHOWING THE U-FACTOR AND SHGC FACTORS SHOWN ON ITEM # 7 |
| | OF THE ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 OF |
| | 2010 FBC-ENERGY CONSERVATION. |
| | |
| | 8- ENGINEER OF RECORD TO PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS FOR MASONRY WALLS SHOWING COMPLIANCE |
| | WITH THE R VALUE SPECIFIED ON ITEM #9. SEC. 103.2.2 OF |
| | 2010 FBC-ENERGY CONSERVATION. |
| | |
| | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED BY THE |
| | ENGINEER ON THE CONNECTOR SCHEDULE. NOTE: ENGINEER MAY |
| | LIST FLORIDA PRODUCT APPROVAL NUMBER NEXT TO THE |
| | SPECIFIED CONNECTOR OR PROVIDE FLORIDA PRODUCT APPROVAL |
| | COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR. |
| | |
| | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC. |
| | |