| Plan Review Notes For Permit 14110349 |
| Permit Number |
14110349 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-11-13 10:27:35 | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 1) INDICATE ON THE PLAN IF THE HANDICAPPED ACCESSIBILE | | | TOILET ROOM IS NEW OR EXISTING. | | | 2) INDDICATE ON THE PLAN WHAT IS EXISTING TO REMAIN AND | | | WHAT WILL BE NEW. | | | 3) THE POSITIONING OF THE SIDE WALL GRAB BAR IN THE | | | ACCESSIBLE TOILET ROOM SHALL COMPLY W/ THE 2010 FL. | | | ACCESSIBILITY CODE SEC. 604.5.1. SEE FIGURE 604.5.1. | | | 4) LIST THE OCCUPANCY TYPE ON THE PLAN IN ACCORDANCE W/ | | | CHAPTER 3 OF THE 2010 FBC. | | | 5) WATER PIPING EXPOSED TO CONCRETE OR PASSING THRU | | | CONCRETE SHALL BE PROTECTED AGAINST EXTERNAL CORROSION | | | IN ACCORDANCE WITH 2010 FL. PLUMBING CODE SEC. 305.1, | | | 305.2, 305.5, & 303.2. | | | 6) THE SANITARY RISER IS NOT DRAWN TO CODE. THE | | | FIXTURES THE SINKS SHALL BE VENTED PER SEC.901.2, | | | 901.2.1. | | | 7) SUBMIT MANUF. SPEC SHEETS FOR THE AVERY BACKWASH | | | SHAMPOO SYSTEM. | | | 8) THE SANITARY RISER SHOWS 2 SINKS AND THE FLOOR PLAN | | | SHOWS 3. CLARIFY. | | | 9) IDENTIFY ON THE PLANS WHAT THE LOFT AREA WILL BE | | | USED FOR.VERTICAL ACCESSIBILITY MAY BE REQUIRED PER THE | | | 2010 FL. ACCESSIBILITY CODE SEC.201.1.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | 2014-11-13 06:53:28 | 1) |
|