| 2014-11-17 14:21:00 | BUILDING PLAN REVIEW |
| | PERMIT: 14110213 |
| | ADD: 222 LAKEVIEW SUITE # 400 |
| | CONT: GREEN CONSTRUCTION |
| | TEL: (305) 670-1000 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. NOV. 17/2014 |
| | ACTION: DENIED |
| | |
| | NOTICE: THE PERMIT APPLICATION INDICATES UNDER THE |
| | HEADING DESCRIPTION OF WORK, TYPED SUITE 400/ |
| | HANDWRITTEN 1ST FLOOR BUILD OUT. THE PLANS INDICATTE |
| | THE WORK IS TO BE COMPLETED ON THE 4TH FLOOR, SO THIS |
| | REVIEW WILL TAKE PLACE AS 4TH FLOOR. CORRECT THE PERMIT |
| | APPLICATION. |
| | |
| | 1) 1) SHEET A-04: |
| | !A) THE (2) NEW ELEVATORS THAT ARE NOT PART OF THIS |
| | CONTRACT WILL EFFECT THE OUTCOME OF THIS PROJECT, |
| | PLEASE INDICATE HOW COMPLIANCE WITH FBC-B 708.14.1 |
| | ELEVATOR LOBBIES OR A EXCEPTION WILL BE COMPLIED WITH. |
| | |
| | |
| | 1B) THE (2) STORAGE ROOMS 403 & 436 ARE LARGE FILE |
| | ROOMS PLEASE PROVIDE WHAT THE FLOOR LOADS FOR THESE |
| | ROOMS ARE DESIGNED, SEE 2010 FBC-B TABLE |
| | 1607.1 (25) OFFICE BUILDINGS- FILE ROOMS SHALL BE |
| | DESIGNED FOR HEAVIER LOADS BASED ON ANTICIPATED |
| | OCCUPANCY. |
| | |
| | 1C) THE COFFEE/ BREAK ROOM # 456 INDICATES A SECTION/ |
| | DETAIL 3/ A-09 THIS IS NOT THE CORRECT DETAILS. SHEET |
| | A-07.6 SHOWS VARIOUS SINK DETAILS. |
| | PLEASE PROVIDE CORRECT SECTION. 107.2.1.3 DISCREPANCY |
| | IN PLANS. |
| | |
| | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO |
| | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA |
| | TUS.ASPX FOR PERMIT STATUS. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |