| Plan Review Notes For Permit 14110211 |
| Permit Number |
14110211 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-11-22 15:08:46 | EXISTING OPENING PROTECTION REQUIRED AS FOLLOWS: | | | | | | | | | R301.2.1.2 PROTECTION OF OPENINGS. | | | WINDOWS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS | | | REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM | | | WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR | | | WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE | | | LARGE MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12 | | | OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN. | | | GARAGE DOOR GLAZED OPENING PROTECTION FOR WINDBORNE | | | DEBRIS SHALL MEET THE REQUIREMENTS OF AN APPROVED | | | IMPACT RESISTING STANDARD OR ANSI/DASMA 115. | | | | | | 1. OPENING IN SUNROOMS, BALCONIES OR ENCLOSED PORCHES | | | CONSTRUCTED UNDER EXISTING ROOFS OR DECKS ARE NOT | | | REQUIRED TO BE PROTECTED PROVIDED THE SPACES ARE | | | SEPARATED FROM THE BUILDING INTERIOR BY A WALL AND ALL | | | OPENINGS IN THE SEPARATING WALL ARE PROTECTED IN | | | ACCORDANCE WITH THIS SECTION. SUCH SPACE SHALL BE | | | PERMITTED TO BE DESIGNED AS EITHER PARTIALLY ENCLOSED | | | OR ENCLOSED STRUCTURES. | | | | | | RECORDS INDICATE STORM PANELS WERE PROVIDED FOR | | | ORIGINAL CONSTRUCTION. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | |
|