| 2014-11-19 18:27:25 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- METAL ROOFING FLORIDA PRODUCT APPROVAL FL11903-R1 | | | SUBMITTED: ONLY THE COVER PAGE WAS SUBMITTED. PROVIDE | | | TWO COPIES OF THE SPECIFIC METAL ROOFING SYSTEM TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. | | | | | | 2- MODIFIED BITUMEN ROOF SYSTEM FLORIDA PRODUCT | | | APPROVAL FL10497-R2 SUBMITTED: | | | A) PROVIDE COMPLETE INFORMATION SHOWING WHICH APPROVED | | | SYSTEM IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | B) IF SELECTED SYSTEM DOESN'T MEET THE REQUIRED DESIGN | | | PRESSURES, THEN NEED TO PROVIDE TWO SIGNED AND SEALED | | | RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER | | | AND CORNER AREAS AS REQUIRED BY NOTE #8 OF FLORIDA | | | PRODUCT APPROVAL FL10497 SUBMITTED. | | | ***NOTE: SEE NOTE #9 IF FULLY BONDED ASSEMBLY IS USED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|