| Date |
Text |
| 2014-11-13 09:58:47 | PLAN REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | BUILDING |
| | |
| | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND |
| | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF |
| | THE PERSON RESPONSIBLE FOR THE DESIGN. |
| | |
| | THE HANDICAP ACCESSIBLE RAMP IS NOT ADA COMPLIANT. 2010 |
| | FBC ACCESSIBILITY. ADDRESS THE FOLLOWING COMMENTS. |
| | |
| | 2) SEC. 405.5 CLEAR WIDTH. THE CLEAR WIDTH OF A RAMP |
| | RUN AND, WHERE HANDRAILS ARE PROVIDED, THE CLEAR WIDTH |
| | BETWEEN HANDRAILS SHALL BE 36 INCHES (915 MM) MINIMUM. |
| | THE PLANS SHOW THE HANDRAILS ARE 36" FROM CENTER TO |
| | CENTER. |
| | |
| | 3) SEC. 405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT |
| | THE TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL |
| | COMPLY WITH 405.7. SECTION 405.7.3 LENGTH. THE LANDING |
| | CLEAR LENGTH SHALL BE 60 INCHES (1525 MM) LONG MINIMUM. |
| | SHOW ON THE PLANS THAT THE LANDING AT THE BOTTOM OF THE |
| | RAMP COMPLIES. |
| | |
| | 4) SEC. 405.8 HANDRAILS. RAMP RUNS WITH A RISE GREATER |
| | THAN 6 INCHES (150 MM) SHALL HAVE HANDRAILS COMPLYING |
| | WITH 505. 505.10 HANDRAIL EXTENSIONS. HANDRAIL GRIPPING |
| | SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION |
| | OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH |
| | 505.10. 505.10.1 TOP AND BOTTOM EXTENSION AT RAMPS. |
| | RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE |
| | LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE TOP |
| | AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A |
| | WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE |
| | CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. SEE |
| | FIGURE 505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT |
| | RAMPS |
| | |
| | 5) SEC. 405.9 EDGE PROTECTION. EDGE PROTECTION |
| | COMPLYING WITH 405.9.1 OR 405.9.2 SHALL BE PROVIDED ON |
| | EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP |
| | LANDINGS. |
| | - 405.9.1 EXTENDED FLOOR OR GROUND SURFACE. THE FLOOR |
| | OR GROUND SURFACE OF THE RAMP RUN OR LANDING SHALL |
| | EXTEND 12 INCHES (305 MM) MINIMUM BEYOND THE INSIDE |
| | FACE OF A HANDRAIL COMPLYING WITH 505. |
| | - 405.9.2 CURB OR BARRIER. A CURB OR BARRIER SHALL BE |
| | PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH (100 MM) |
| | DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS |
| | WITHIN 4 INCHES (100 MM) OF THE FINISH FLOOR OR GROUND |
| | SURFACE. |
| | |
| | 6) 405.10 WET CONDITIONS. LANDINGS SUBJECT TO WET |
| | CONDITIONS SHALL BE DESIGNED TO PREVENT THE |
| | ACCUMULATION OF WATER. (405.3 CROSS SLOPE. CROSS SLOPE |
| | OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48.) |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |