| Plan Review Notes For Permit 14100710 |
| Permit Number |
14100710 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-10-22 18:50:03 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- FLAT ROOF: | | | A) CLEARLY SPECIFY WHICH APPROVED ASSEMBLY FROM NOA | | | 13-0529.02 SUBMITTED IS GOING TO BE INSTALLED. SEC. | | | 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED. NEED THE RAS 117 CALCULATIONS TO COMPLY WITH | | | THE DESIGN PRESSURES OF SEC. R301 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|