| 2014-11-25 18:46:55 | RESIDENTIAL (R3) SCREEN ENCLOSURE, BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- DESIGNER OF RECORD TO PROVIDE NAME AND SIGNATURE ON |
| | THE SITE SPECIFIC LAYOUT AS REQUIRED BY SEC. 107.2.1 |
| | CITY AMENDMENTS TO FBC. |
| | ***NOTE: SCREEN ENCLOSURE DIMENSIONS MAY NEED TO BE |
| | REVISED. SEE ZONING COMMENTS. |
| | |
| | 2- CLARIFY SCREEN ENCLOSURE SITE SPECIFIC DRAWINGS. IS |
| | THIS A FLAT ROOF SCREEN ENCLOSURE OR PITCHED ROOF?. IS |
| | THERE A 2X9 BEAM OR 3X3 EAVE RAIL?. PLANS ARE NOT |
| | CLEAR. REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS |
| | TO FBC. |
| | |
| | 3- PROVIDE CORRECT TABLE FOR THE ALLOWABLE BEAM SPAN TO |
| | MATCH PLANS. IT LOOKS LIKE THIS IS A FLAT ROOF SCREEN |
| | ENCLOSURE, NOT PITCHED. COORDINATE WITH ITEM #2 ABOVE. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 4- PROVIDE ONLY THE DETAILS AND TABLES THAT APPLY TO |
| | THIS PROJECT TO AVOID DISCREPANCIES OR CONFLICTS. SEC. |
| | 107.2.1 CITY AMENDMENTS |
| | |
| | 5- THE ALLOWABLE POST HEIGHT FOR 3/8 CONCRETE FASTENERS |
| | ON TABLE 105 SUBMITTED IS 7.7'. THIS HEIGHT DOESN'T |
| | REFLECT PLANS. REVISE AS REQUIRED TO COMPLY. SEC. |
| | R301.1 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 6- ALLOWABLE BEAM SPAM FOR RIBBON FOOTINGS TABLE 111 |
| | SUBMITTED IS FOR EXPOSURE "B". REVISE AS REQUIRED. |
| | HOUSE IS LOCATED IN EXPOSURE "C". SEC. R301 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |