| 2015-01-02 09:36:45 | REVIEW BY JWITMER. |
| 2014-12-16 14:26:41 | BUILDING PLAN REVIEW |
| | PERMIT: 1410069 |
| | ADD: 222 LAKEVIEW SUITE # 300 |
| | CONT: GREEN CONSTRUCTION |
| | TEL: (305) 670-1000 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: TUES. DEC. 16/2014 |
| | ACTION: BUILDING PROVISO |
| | |
| | NOTICE: THE PERMIT APPLICATION UNDER DISCREPTION OF |
| | WORK: TYPED SUITE 300/ HAND WRITTEN 1ST FLOOR BUILD |
| | OUT, THIS REVIEW WILL BE FOR A 3RD FLOOR BUILDOUT AS |
| | STATED ON PLANS. |
| | |
| | |
| | PERMIT # 14081026 FOR ELEVATORS/ SHAFTS |
| | & PRESSURIZATION OF SHAFT |
| | |
| | BLDG. PROVISO: |
| | |
| | PRIVATE RESTROOM # 355: |
| | |
| | 2010 FL ACCESS. CODE 609.4 POSITION OF GRAB BARS. |
| | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| | THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR |
| | CHILDREN?S USE COMPLYING WITH 604.9, GRAB BARS SHALL BE |
| | INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) |
| | MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE |
| | HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A |
| | BATHTUB SHALL COMPLY WITH 607.4.1.1 OR 607.4.2.1. |
| | |
| | 2010 FL. ACCESS. CODE 609.8 STRUCTURAL STRENGTH. |
| | ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS |
| | USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS |
| | (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, |
| | FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. |
| | |
| | JAMES A. WITMER CBO |