| Plan Review Notes For Permit 14090908 |
| Permit Number |
14090908 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-10-20 10:37:41 | 1) 5 % BUT NO LESS THAN ONE OF THE SINKS IN THE EXAM | | | ROOMS AND OTHER ROOMS SHALL COMPLY WITH THE 2010 | | | FLORIDA ACCESSIBILITY CODE SECS. 212.3, 306, & 606. | | | 2) SHT. P-2 - SIZE ALL SECTIONS OF THE SANITARY AND | | | WATER RISER DIAGRAMS. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 3) SHT. P-2 - DRAINS FOR SINKS IN ROOMS 187 & 188 ARE | | | DRAWN IN THE OPPOSITE DIRECTION OF FLOW AT THE | | | CONNECTION TO THE EXISTING LINE. | | | 4) SHT. P-2 - THE HUB DRAIN IN ROOM #205 REQUIRES A | | | TRAP SEAL PER THE 2010 FPC SECS. 1002.1, 1002.4. | | | 5) SHT. P-2 - THE BREAK ROOM SINK IS NOT SHOWN ON THE | | | SANITARY RISER. WPB AMEND. TO 2010FBC SEC.107.2.1. | | | 6) THE SINK IN RM. #188 IS NOTED AS EXISTING ON THE | | | SANITARY RISER BUT AS NEW ON THE WATER RISER. CLARIFY. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|