| Date |
Text |
| 2014-10-01 14:25:05 | BUILDING PLAN REVIEW |
| | PERMIT: 14090908 |
| | ADD: 901 VILLAGE BLVD SUITE 702 |
| | CONT: PM BUILDERS |
| | TEL: (561)330-3833 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. OCT. 01 /2014 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE PROVIDE THE MINIMUM PLAN REVIEW CRITERIA FOR |
| | BUILDINGS: |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.3.5 MINIMUM PLAN |
| | REVIEW CRITERIA FOR BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 107.3.5.1.1 BUILDING |
| | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| | SHALL BE DETERMINED. |
| | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE |
| | TABLE 503). |
| | FIRE SPRINKLERED OR NOT THIS WILL AFFECT TRAVEL LENGTHS |
| | AND DEAD ENDS. |
| | |
| | 2A) PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE PHASED |
| | SCOPE OF WORK WITH EXIT SIGNS AND DIRECTIONAL SIGNAGE. |
| | 2010 FBC-B 1006.3.1 & 1006.3.8. |
| | |
| | 2B) THE ELECTRICAL SHEETS SHOW A EXIT SIGN THROUGH THE |
| | NEURO FEEDBACK ROOM, 2010 FBC-B 1014.2 EGRESS THROUGH |
| | INTERVENING SPACES 4. EGRESS SHALL NOT PASS THROUGH |
| | KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR |
| | SIMILAR PURPOSES. ROOMS THAT CAN BE LOCKABLE. |
| | |
| | 3) SHEET S-1 INDICATES THE USE OF NEW STOREFRONT |
| | WINDOWS AND DOORS. PLEASE PROVIDE COMPLIANCE WITH: |
| | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| | COMPONENTS & CLADDING |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, |
| | |
| | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 5) INTERIOR DECORATOR PLANS DESIGNED BY P2 INTERIORS, |
| | LICENSE # IB26001537 ARE NOT SIGNED NOR SEALED. |
| | 61G1-16.003 USE OF SEAL. EFFECTIVE 04/18/2000 THE |
| | PERSONAL SEAL, SIGNATURE AND DATE OF THE ARCHITECT OR |
| | INTERIOR DESIGNER SHALL APPEAR ON ALL ARCHITECTURAL OR |
| | INTERIOR DESIGN DOCUMENTS TO BE FILED FOR PUBLIC |
| | RECORD. |
| | |
| | 6) IMPACT FEES- NOT REQUIRED. |
| | |
| | 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |